Description
Status
AMP status LED
• Off = AMP modes disabled
• Solid green = AMP mode enabled
• Solid amber = Failover
• Flashing amber = Invalid configuration
Power cap LED
• Off = System is in standby, or no cap is set
• Solid green = Power cap applied
For Networking Choice server models, the embedded NIC ports are not equipped on the server. Therefore, the NIC LEDs on the Systems
Insight Display will flash based on the FlexibleLOM network port activity. In the case of a dual
‑
port FlexibleLOM, only NIC LED 1 and 2
will illuminate to correspond with the activity of the respective network ports.
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. For
more information on the combination of these LEDs, see
Systems Insight Display combined LED descriptions.
Systems Insight Display combined LED descriptions
The combined illumination of the following LEDs indicates a system condition:
• Systems Insight Display LEDs
• System power LED
• Health LED
Systems Insight Display LED
and color
Health LED System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions
might exist:
• Processor in socket X has failed.
• Processor X is not installed in the
socket.
• Processor X is unsupported.
• ROM detects a failed processor during
POST.
Processor (amber)
Amber
Green
Processor in socket X is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a
cautionary temperature level.
Table Continued
Component identification
115
Содержание ProLiant DL385 Gen10
Страница 30: ...30 Customer self repair...
Страница 31: ...Customer self repair 31...
Страница 32: ...32 Customer self repair...
Страница 129: ...8LFF front panel 12LFF front panel Midplane box LFF only Component identification 129...
Страница 141: ...Rear 2SFF to system board Cable routing Front 8SFF SAS SATA drive options Box 1 to SAS Expander Cabling 141...
Страница 142: ...Boxes 2 and 3 to SAS Expander All boxes to SAS Expander 142 Cabling...
Страница 143: ...Cable routing Midplane 4LFF SAS SATA drive option Cabling 143...
Страница 145: ...Cable routing Rear 3LFF SAS SATA drive option for system board Cabling 145...
Страница 147: ...Cable routing Front 2SFF NVMe side by side drive options Cabling 147...
Страница 149: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 149...
Страница 150: ...Box 3 150 Cabling...
Страница 153: ...Cable routing Power switch module SID module An SFF model is shown The routing is the same for LFF Cabling 153...