background image

Operations

Removing the bezel

Procedure

1. Remove the Kensington security lock.

2. Remove the bezel.

a. Press the latch.

b. Open the bezel.

c. Detach the bezel from the latch ear.

Powering up the server

Procedure

1. Remove the bezel.

2. Use one of the following methods to power up the server:

• Press the Power On/Standby button.

• Use the virtual power button through iLO.

3. Install the bezel.

Operations

27

Содержание ProLiant DL325 Gen10 Plus

Страница 1: ...20 Edition 2 Abstract This document is for the person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes you are qualified in the servicing of co...

Страница 2: ...for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard...

Страница 3: ...ons 21 uFF drive components and LEDs 22 PCIe expansion slot definitions 23 PCIe4 slot description 24 Riser board components 25 Fan bay numbering 26 Operations 27 Removing the bezel 27 Powering up the...

Страница 4: ...stalling a uFF drive and SCM drive carrier 69 Drive cage options 71 Installing a 2SFF SAS SATA NVMe or uFF drive cage 71 Upgrading 4LFF to 8LFF 73 Upgrading 8SFF to 16SFF 74 Riser cage options 76 Inst...

Страница 5: ...ing Chassis intrusion detection switch 121 Cable routing M 2 enablement board 121 Cable routing Controller backup power cable 121 Cable routing Energy pack 122 Software and configuration utilities 123...

Страница 6: ...upply specifications 140 HPE 500W Flex Slot Platinum Hot plug Low Halogen Power Supply 140 HPE 800W Flex Slot Platinum Hot plug Low Halogen Power Supply 141 HPE 800W Flex Slot Titanium Hot plug Low Ha...

Страница 7: ...service port 4 USB 3 0 port 5 LFF drive bays up to 12 LFF drives SFF SAS SATA NVMe drive model Item Description 1 Serial label pull tab 2 Optical drive cage optional for short chassis only 3 2SFF SAS...

Страница 8: ...www hpe com qref dl325gen10plus This page contains links to server setup information spare part numbers QuickSpecs troubleshooting resources and other useful product links Front panel LEDs and buttons...

Страница 9: ...2 1 If the health LED indicates a degraded or critical state review the system Integrated Management Log IML or use HPE iLO to review the system health status 2 If the system power LED is off verify...

Страница 10: ...h per second Remote management or firmware upgrade in progress 4 flashes per second iLO manual reboot sequence initiated 8 flashes per second iLO manual reboot sequence in progress Off Deactivated 1 I...

Страница 11: ...vior System board 1 flash Processor 2 flashes Memory 3 flashes Riser board PCIe slots 4 flashes FlexibleLOM 5 flashes Removable HPE Smart Array SR Gen10 controller 6 flashes System board PCIe slots 7...

Страница 12: ...Flashing green Network active Off No network activity 3 UID Solid blue Activated Flashing blue 1 flash per sec Remote management or firmware upgrade in progress 4 flashes per sec iLO manual reboot seq...

Страница 13: ...troller backup power connector 2 5 GPU power connector 2 6 Primary PCIe riser connector 7 System battery 8 NVMe port 6A 9 OCP NIC 3 0 connector 10 OCP X16 upgrade connector 11 Internal USB 3 0 connect...

Страница 14: ...connector 1 32 Smart Array modular controller connector NVMe port 7A 33 Drive backplane power connector 3 34 Drive backplane power connector 2 35 Chassis intrusion detection switch connector 36 Drive...

Страница 15: ...stem maintenance switch position 6 is set to the On position and Secure Boot is enabled some configurations cannot be restored For more information see Secure Boot DIMM slot locations DIMM slots are n...

Страница 16: ...5 Maximum memory speed 3200 MT s 6 CAS latency AA CAS 22 22 22 AA CAS 26 22 22 for 3DS LRDIMM 7 DIMM type R RDIMM registered L LRDIMM load reduced For more information about product features specific...

Страница 17: ...t components Item Description 1 Pin field 2 Rail frame 3 Carrier frame 4 Processor 5 Force frame 6 Captive screws Torx T 20 Drive box identification LFF drive model Short chassis Long chassis Componen...

Страница 18: ...Item Description 1 Box 1 2 Box 21 3 Box 31 1 Optional SFF drive model Short chassis Long chassis NOTE 2SFF drive cage is not supported in long chassis configuration 18 Component identification...

Страница 19: ...numbering LFF drive model Box 1 Box 2 Box 3 SFF drive model Short Chassis Box 1 Box 2 Drive numbering color Description Green 8SFF SAS SATA NVMe drives Orange 2SFF SAS SATA NVMe drives optional Blue D...

Страница 20: ...ed in box 3 only 2NVMe drives are supported in box 4 using 1 port NVMe adapter due to the cabling limitation Long chassis Box 1 Drive numbering color Description Green 8SFF SAS SATA NVMe drives Long c...

Страница 21: ...green The drive is online and has no activity Flashing green 4 flashes per second The drive is operating normally and has activity Flashing green 1 flash per second The drive is doing one of the foll...

Страница 22: ...g green The drive is doing one of the following Rebuilding Performing a RAID migration Performing a strip size migration Performing a capacity expansion Performing a logical drive extension Erasing Sp...

Страница 23: ...ration capacity expansion logical drive extension or is erasing Flashing amber green 1 Hz The drive is a member of one or more logical drives that predicts the drive will fail Solid amber The drive ha...

Страница 24: ...PCIe 3 x PCIe 4 x The PCIe technology is under constant development For the latest information see the PCI SIG website 2 Physical connector link width PCIe devices communicate through a logical conne...

Страница 25: ...Description 1 PCIe4 x16 16 8 4 1 slot 2 PCIe4 x16 16 8 4 1 slot Slimline primary riser Item Description 1 PCIe4 x16 16 8 4 1 slot 2 3 Slimline connectors Standard secondary riser Item Description 1 P...

Страница 26: ...Slimline secondary riser Item Description 1 2 Slimline connectors Fan bay numbering The arrow points to the front of the server 26 Component identification...

Страница 27: ...el a Press the latch b Open the bezel c Detach the bezel from the latch ear Powering up the server Procedure 1 Remove the bezel 2 Use one of the following methods to power up the server Press the Powe...

Страница 28: ...ndby mode Press and hold the Power On Standby button for more than 4 seconds to force the server to enter standby mode This method forces the server to enter standby mode without properly exiting appl...

Страница 29: ...dure 1 To fully extend the long chassis server with the cable management arm do the following NOTE If the cable management arm option is installed for a short chassis server you can extend the server...

Страница 30: ...management arm 2 Extend the server from the rack a Open the latches on both sides of the server b If necessary use a T 25 Torx screwdriver to loosen the shipping screws c Slide the server out of the...

Страница 31: ...duct is not fastened to the rails Hewlett Packard Enterprise recommends that a minimum of two people are required for all rack server installations If the server is installed higher than chest level a...

Страница 32: ...installed remove the bezel 2 Power down the server 3 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconnect all peripheral cables...

Страница 33: ...against the chassis wall 2 For the long chassis install three screws on each side Removing the access panel CAUTION Do not operate the server for long periods with the access panel open or removed Op...

Страница 34: ...isengage the access panel from the chassis press the release button and pull up the latch c Lift the access panel Installing the access panel Prerequisites Before you perform this procedure make sure...

Страница 35: ...3 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconnect all peripheral cables from the server 5 Remove the server from the rack...

Страница 36: ...10 Remove the inner drive cage blank 11 Remove the fan wall covers 36 Operations...

Страница 37: ...12 For SFF drive cage remove the cable covers 13 Remove the drive cage latches Operations 37...

Страница 38: ...14 Remove the outer drive cage LFF SFF 38 Operations...

Страница 39: ...is procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Install the outer drive cage a Slide the outer cage to engage with spools on the base pan of the chassis b Secure the...

Страница 40: ...hassis route cables through the routing holes on the middle wall For SFF chassis route cables along both the side walls 4 For SFF chassis install the cable covers on both sides of the chassis 5 Instal...

Страница 41: ...6 Connect all drive cables 7 Secure all drive signal cables with the cable tie 8 Install the inner drive cage blank Operations 41...

Страница 42: ...d install the bezel Removing an inner drive cage Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 If installed remove the bezel 2 P...

Страница 43: ...ystem board or expansion boards 9 Remove the fan wall covers 10 Remove the inner drive cage Installing an inner drive cage Prerequisites Before you perform this procedure make sure that you have a T 1...

Страница 44: ...ner drive cage is heavy Be careful while installing the cage as it might cause finger injury 2 If removed install the drives in the inner drive cage 3 Secure the cage to the chassis a Press and hold t...

Страница 45: ...CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amount of time...

Страница 46: ...lowing alert CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amo...

Страница 47: ...To prevent damage to the server or expansion boards power down the server and disconnect all power cords before removing or installing the riser board Procedure 1 If installed remove the bezel 2 Power...

Страница 48: ...Secondary riser cage Installing a riser cage Procedure 1 Install the riser cage Primary riser cage Secondary riser cage 48 Operations...

Страница 49: ...age do not operate the server unless all PCI slots have either a riser blank or an expansion board installed Prerequisites Before you perform this procedure make sure that you have a T 15 Torx screwdr...

Страница 50: ...er blank from primary riser remove the primary riser cage 8 Remove the riser blank Primary riser slot 1 Primary riser slot 2 Secondary riser slot 3 low profile blank Secondary riser slot 3 full height...

Страница 51: ...emove the bezel 2 Power down the server 3 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconnect all peripheral cables from the s...

Страница 52: ...52 Operations...

Страница 53: ...th hardware and software Hewlett Packard Enterprise Education Services Help train your IT staff 1The time commitment for this repair service might vary depending on the geographical region of site For...

Страница 54: ...er Download the latest SPP http www hpe com servers spp download Support validation required Verify that your OS or virtualization software is supported http www hpe com info ossupport Read the HPE UE...

Страница 55: ...ng a browser navigate to the iLO web interface and then log in https iLO hostname or IP address Note the following The iLO hostname is on the serial number iLO information pull tab If a DHCP server as...

Страница 56: ...and then create an array a From the boot screen press F9 to run UEFI System Utilities b From the UEFI System Utilities screen select System Configurations BIOS Platform Configuration RBSU Storage Opti...

Страница 57: ...alled in uFF Port 1 Port 5 20SFF 8 2 SATA 8 2 SATA Box 4 Bay 1 if OS is to be installed in 2SFF Port 1 To identify exact drive bay location see Drive box identification and Drive bay numbering For mor...

Страница 58: ...ng a rack without blanking panels results in improper cooling that can lead to thermal damage The 9000 and 10000 Series Racks provide proper server cooling from flow through perforations in the front...

Страница 59: ...64 parts 1 through 7 Furthermore you must be sure that all power distribution devices used in the installation such as branch wiring and receptacles are listed or certified grounding type devices Beca...

Страница 60: ...he server in this manner results in improper airflow and improper cooling that can lead to thermal damage CAUTION Do not operate the server for long periods with the internal drive cage open Operating...

Страница 61: ...onnected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground w...

Страница 62: ...e Installation Instructions on the Hewlett Packard Enterprise website 2 Install the server into the rack a Align the inner rails of the server with the outer rails b Slide the server into the rack unt...

Страница 63: ...e UEFI requirements for ProLiant Gen10 servers can result in errors installing the operating system failure to recognize boot media and other boot failures For more information on these requirements s...

Страница 64: ...Installing or deploying an operating system Before installing an operating system observe the following Be sure to read the HPE UEFI requirements for ProLiant servers on the Hewlett Packard Enterprise...

Страница 65: ...ver specific information use the procedures in this section If multiple options are being installed read the installation instructions for all the hardware options to identify similar steps and stream...

Страница 66: ...greatest storage space efficiency when grouped into the same drive array Installing a hot plug SAS SATA or NVMe drive Procedure 1 To install a drive in outer drive cage remove the bezel if installed 2...

Страница 67: ...3 Remove the drive blank LFF SFF 4 Prepare the drive LFF Hardware options installation 67...

Страница 68: ...SFF 5 Install the drive LFF SFF 6 Observe the LED status of the drive 7 If the drive is installed in inner cage press the inner drive cage down 68 Hardware options installation...

Страница 69: ...nstall the uFF drive into the drive carrier 2 To install a drive in outer drive cage remove the bezel If installed 3 To install a drive in inner drive cage do the following NOTE If the HPE designated...

Страница 70: ...spring engages with the drive bay 6 Observe the LED status of the drive 7 If the drive is installed in inner cage press the inner drive cage down 8 Slide the server in the rack 9 If removed install t...

Страница 71: ...l power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconnect all peripheral cables from the server 5 Remove the server from the rack 6 Remove th...

Страница 72: ...ive backplane 2SFF SAS SATA or uFF 2SFF NVMe 13 Install the cable guard 14 Install the outer drive cage 15 Install an SFF drive SAS SATA or NVMe drive uFF drive 16 Install the access panel 17 Install...

Страница 73: ...ites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 If installed remove the bezel 2 Power down the server 3 Remove all power a Disconnect each...

Страница 74: ...s panel 16 Install the inner rack rails 17 Install the server into the rack 18 Connect all peripheral cables to the server 19 Connect each power cord to the server 20 Connect each power cord to the po...

Страница 75: ...l cables from the server 5 Remove the server from the rack 6 Remove the inner rack rails 7 Remove the access panel 8 Remove the inner drive cage blank 9 Remove the fan wall covers 10 Remove all the ex...

Страница 76: ...mplete Riser cage options Installing the secondary low profile PCIe riser cage When installed this riser cage provides an additional low profile slot and supports half height half length expansion boa...

Страница 77: ...ing the secondary full height PCIe riser cage When installed this riser cage supports full height half length expansion boards PCIe slot 2 is no longer available Prerequisites Before you perform this...

Страница 78: ...iser cage 8 Remove the primary riser cage 9 Remove the slot 2 bracket of the primary riser cage 10 Install the primary riser cage 11 Remove the secondary low profile bracket 12 Install the full height...

Страница 79: ...er 17 Connect each power cord to the server 18 Connect each power cord to the power source 19 Power up the server 20 If removed install the bezel The installation is complete Storage controller option...

Страница 80: ...st unit to be powered down and the last to be powered back up Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up Procedure 1 If...

Страница 81: ...in controller is supported in slot 2 and slot 3 only due to cabling limitation NOTE If the slimline primary riser is installed the controller is not supported in slot 2 NOTE If the slimline secondary...

Страница 82: ...n systems that use external data storage be sure that the server is the first unit to be powered down and the last to be powered back up Taking this precaution ensures that the system does not erroneo...

Страница 83: ...e primary riser cage b Remove the primary riser blank c Install the controller Primary riser slot 2 d Install the primary riser cage 10 If installing a PCIe plug in controller in the secondary riser a...

Страница 84: ...cord to the server 17 Connect each power cord to the power source 18 Power up the server 19 Configure the storage controller 20 If removed install the bezel The installation is complete Configuring a...

Страница 85: ...ass Smart Array controllers Once installed the status of the energy pack displays in HPE iLO For more information see the HPE iLO user guide on the Hewlett Packard Enterprise website https www hpe com...

Страница 86: ...umbering 8 Install the energy pack a Insert the energy pack at an angle b Push the release latch in backward direction c Push the energy pack down from other end d Connect the energy pack cable and se...

Страница 87: ...rm this procedure make sure that you have the following items available Expansion board option kit Internal and external cabling required by the expansion board T 15 Torx screwdriver Procedure 1 If in...

Страница 88: ...et on the expansion board 9 If installing an expansion board in the primary riser a Remove the primary riser cage b Remove the primary riser blank c Install the expansion board Primary riser slot 1 88...

Страница 89: ...iser blank b Install the secondary riser cage c Install the expansion board 11 Connect all necessary internal cabling to the expansion board For more information on these cabling requirements see the...

Страница 90: ...procedure make sure that you have the following items available SAS expander option Internal and external cabling required by the SAS expander Smart Array type a modular controller installed T 15 Tor...

Страница 91: ...e bezel The installation is complete Installing the M 2 SSD enablement option Prerequisites Before you perform this procedure make sure that you have the following items available T 15 Torx screwdrive...

Страница 92: ...the M 2 SSD enablement board 11 Install the riser cage 12 Connect the SATA cables 13 Install the access panel 14 Install the server into the rack 15 Connect all peripheral cables to the server 16 Con...

Страница 93: ...power cord from the server 4 Disconnect all peripheral cables from the server 5 Remove the server from the rack 6 Remove the inner rack rails 7 Remove the access panel 8 Do one of the following Remov...

Страница 94: ...f the following Install the inner drive cage Install the inner drive cage blank 15 Install the access panel 16 Install the inner rack rails 17 Install the server into the rack 18 Connect all periphera...

Страница 95: ...vailable Procedure 1 If installed remove the bezel 2 Power down the server 3 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconne...

Страница 96: ...11 Connect the SATA power Y cable to ODD 12 Install the ODD cage assembly 13 Do one of the following Remove the inner drive cage Remove the inner drive cage blank 96 Hardware options installation...

Страница 97: ...ack rails 18 Install the server into the rack 19 Connect all peripheral cables to the server 20 Connect each power cord to the server 21 Connect each power cord to the power source 22 Power up the ser...

Страница 98: ...Single rotor fan Single rotor fan Single rotor fan Single rotor fan Single rotor fan Single rotor fan Single rotor fan Single rotor fan 4LFF or 8SFF with HPE Smart Storage Battery and InfiniBand card...

Страница 99: ...To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent improper cooling and thermal damage do not...

Страница 100: ...M population information see the DIMM population guidelines on the Hewlett Packard Enterprise website https www hpe com docs amd population rules Gen10Plus Memory speed tables For specific DDR4 server...

Страница 101: ...ave positioned it incorrectly Reverse the orientation of the DIMM and insert it again 8 Install the access panel 9 Install the server into the rack 10 Connect all peripheral cables to the server 11 Co...

Страница 102: ...n switch a Connect the intrusion detection switch cable b Press the switch towards the chassis c Slide the switch into the slot on the chassis 8 Install the access panel 9 Install the server into the...

Страница 103: ...Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 4 Disconnect all peripheral cables from the server 5 Remove the server from the rack 6...

Страница 104: ...ns and calculators to determine electrical and heat loading for the server see the Hewlett Packard Enterprise Power Advisor website https www hpe com info poweradvisor online Installing a redundant ho...

Страница 105: ...r cord to the power supply 5 Secure the power cord in the strain relief strap attached to the power supply handle a Unwrap the strain relief strap from the power supply handle CAUTION Avoid tight bend...

Страница 106: ...ails For installing rack rails see the installation instructions on the Hewlett Packard Enterprise website Installing the cable management arm For installing the cable management arm see the installat...

Страница 107: ...gth of the cable Use the internal cable management features to properly route and secure the cables When routing cables be sure that the cables are not in a position where they can be pinched or crimp...

Страница 108: ...erver can restrict airflow If you intend to use the removed cables later label and store them for future use Cable routing 4 8LFF drive model 4 LFF SATA box 1 connected to system board 4 LFF SAS SATA...

Страница 109: ...8 LFF SATA box 1 and 2 connected to system board 8 LFF SAS SATA box 1 and 2 connected to HPE Smart Array type a modular controller Cabling 109...

Страница 110: ...LFF drive power cable Cable color Description Orange Power cable from box 1 drive backplane to system board power connector 1 Blue Power cable from box 2 drive backplane to system board power connect...

Страница 111: ...ription Orange Mini SAS cable from box 1 drive backplane port 1 to type a controller port 1 Blue Mini SAS cable from box 1 drive backplane port 2 to type a controller port 2 Gold Mini SAS cable from b...

Страница 112: ...color Description Orange Mini SAS cable from box 1 drive backplane port 1 to type a controller port 1 Blue Mini SAS cable from box 1 drive backplane port 2 to type a controller port 2 Gold Mini SAS c...

Страница 113: ...le from SAS expander port 7 to box 3 drive backplane port 2 Green Mini SAS cable from SAS expander port 1 to type a controller port 1 Black Mini SAS cable from SAS expander port 2 to type a controller...

Страница 114: ...Cable routing 8 16 NVMe drive model 8NVMe drives box 1 connected to system board Item Description Orange Slimline cable from box 1 drive backplane port 1 to NVMe port 3A on system board Blue Slimline...

Страница 115: ...rt 2A on system board Pink Slimline cable from box 3 drive backplane port 4 to port 6A on system board Green Slimline cable from box 4 drive backplane port 1 to port 7A on 1 port NVMe adapter Power ca...

Страница 116: ...pe p storage controller installed in slot 2 The cabling for type p storage controller installed in slot 3 is similar 2SFF SAS SATA uFF drives installed in outer and inner cages box 2 and 4 and connect...

Страница 117: ...controller port 1 Blue Mini SAS cable from box 4 drive backplane port 1 to type p controller port 2 Power cabling Cable color Description Orange Power cable from box 1 8SFF drive backplane to box 2 2...

Страница 118: ...configuration the 2NVMe drives installed in inner cage box 4 are connected to 1 port NVMe adapter Cable color Description Orange Slimline SAS cable from box 2 drive backplane port 1 to system board p...

Страница 119: ...SFF Cable routing Front I O LFF Cabling 119...

Страница 120: ...SFF Cable routing Serial port 120 Cabling...

Страница 121: ...g for M 2 enablement board installed in slot 3 The cabling for M 2 enablement board installed in slot 1 or 2 is similar Cable routing Controller backup power cable This illustration shows the cabling...

Страница 122: ...Cable routing Energy pack 122 Cabling...

Страница 123: ...tion about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise website https www hpe com info qs Active Health System...

Страница 124: ...logging of Active Health System data When the Active Health System Log is full new data overwrites the oldest data in the log It takes less than 5 minutes to download the Active Health System Log and...

Страница 125: ...license is required for using the following features Group virtual media Group power control Group power capping Group configuration and Group firmware update For more information about iLO Federatio...

Страница 126: ...on that enables rapid discovery detailed inventory reporting firmware and driver updates by leveraging iLO advanced functionality iLO Amplifier Pack performs rapid server discovery and inventory for t...

Страница 127: ...ning or HPE Rapid Setup Software From the iLO web interface using Always On Always On allows you to access Intelligent Provisioning without rebooting your server Intelligent Provisioning operation NOT...

Страница 128: ...utilities and important documentation that describes how to apply these tools to build an automated server deployment process The STK provides a flexible way to create standard server configuration s...

Страница 129: ...Mode Configures the system to boot to a traditional operating system in Legacy BIOS compatibility mode 3 Save your setting 4 Reboot the server Secure Boot Secure Boot is a server security feature that...

Страница 130: ...ell The Embedded UEFI Shell screen appears 2 Press any key to acknowledge that you are physically present This step ensures that certain features such as disabling Secure Boot or managing the Secure B...

Страница 131: ...and performance monitoring of Active Health System AHS and HPE iLO to optimize performance and predict and prevent problems Provides automatic collection and analysis of the sensor and telemetry data...

Страница 132: ...em HPE Synergy and HPE Apollo servers and infrastructure SPP can be used in an online mode on a server running Windows Linux or VMware vSphere ESXi or in an offline mode where the server is booted to...

Страница 133: ...r servers Communicates with iSUT or SUT 1 x to initiate updates using the iLO Redfish interface iSUT reports the status of updates to iLO Amplifier Pack via iLO Restful Interface SPP A comprehensive s...

Страница 134: ...intained Online Flash components This component provides updated system firmware that can be installed directly on supported operating systems Additionally when used in conjunction with SUM this Smart...

Страница 135: ...tributes Operational Support Services enable you to choose the right service level length of coverage and response time to fit your business needs For more information see the Hewlett Packard Enterpri...

Страница 136: ...liquid or gas Do not disassemble crush puncture short external contacts or dispose the battery in fire or water If the server no longer automatically displays the correct date and time then replace th...

Страница 137: ...2 Connect all peripheral cables to the server 13 Connect each power cord to the server 14 Connect each power cord to the power source 15 Power up the server 16 If removed install the bezel 17 Properly...

Страница 138: ...e iLO Virtual NMI feature Troubleshooting resources Troubleshooting resources are available for HPE Gen10 server products in the following documents Troubleshooting Guide for HPE ProLiant Gen10 server...

Страница 139: ...aximum rate of change is 20 C hr 36 F hr The upper limit and rate of change may be limited by the type and number of options installed System performance during standard operating support may be reduc...

Страница 140: ...gen Power Supply HPE 800W Flex Slot Platinum Hot plug Low Halogen Power Supply HPE 800W Flex Slot Titanium Hot plug Low Halogen Power Supply HPE 800W Flex Slot Universal Hot plug Low Halogen Power Sup...

Страница 141: ...0 W at 100 VAC to 127 VAC input 500 W at 100 VAC to 240 VAC input 500 W at 240 VDC input for China only HPE 800W Flex Slot Platinum Hot plug Low Halogen Power Supply Specification Value Input requirem...

Страница 142: ...t for China only HPE 800W Flex Slot Titanium Hot plug Low Halogen Power Supply Specification Value Input requirements Rated input voltage 200 VAC to 240 VAC 240 VDC for China only Rated input frequenc...

Страница 143: ...ut requirements Rated input voltage 200 VAC to 277 VAC 380 VDC Rated input frequency 50 Hz to 60 Hz Rated input current 4 4 A at 200 VAC 3 1 A at 277 VAC 2 3 A at 380 VDC Maximum rated input power 869...

Страница 144: ...t nominal input 2912 at 72 VDC input Power supply output Rated steady state power W 800 W at 40 VDC to 72 VDC Maximum peak power W 800 W at 40 VDC to 72 VDC Maximum peak power 800 W at 40 VDC to 72 VD...

Страница 145: ...of earthing of the DC system The DC system must be earthed elsewhere The DC supply source is to be located within the same premises as the equipment Switching or disconnecting devices must not be in t...

Страница 146: ...rs and analyst reports https www hpe com storage whitepapers For additional websites see Support and other resources Product websites HPE ProLiant DL325 Gen10 Plus Server product page https www hpe co...

Страница 147: ...essing updates Some software products provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update met...

Страница 148: ...PE Proactive Care service Supported products list https www hpe com services proactivecaresupportedproducts HPE Proactive Care advanced service Supported products list https www hpe com services proac...

Страница 149: ...com info ecodata For Hewlett Packard Enterprise environmental information including company programs product recycling and energy efficiency see https www hpe com info environment Documentation feedb...

Отзывы: