135
mdc-admin
mdc-operator
Parameters
pse-id
: Specifies a PSE by its ID. If you do not specify a PSE, this command displays information
about all PSEs.
Usage guidelines
This command is only available for the default MDC. For more information about MDCs, see
Virtual
Technologies Configuration Guide
.
Examples
# (In standalone mode.) Display detailed information about PSE 7.
<Sysname> display poe pse 7
PSE ID : 7
Slot No. : 2
PSE Model : LSQ1GV48SD0
PSE Status : Enabled
Power Priority : Low
Current Power : 0.0 W
Average Power : 0.0 W
Peak Power : 0.0 W
Max Power : 800.0 W
Remaining Guaranteed Power : 800.0 W
PSE CPLD Version : -
PSE Software Version : 390
PSE Hardware Version : 57603
Legacy PD Detection : Disabled
Power Utilization Threshold : 80
PD Power Policy : Disabled
PD Disconnect-Detection Mode : DC
# (In IRF mode.) Display detailed information about PSE 7.
<Sysname> display poe pse 7
PSE ID : 7
Chassis : 1
Slot No. : 2
SSlot No. : 0
PSE Model : LSQ1GV48SD0
PSE Status : Disabled
Power Priority : Low
Current Power : 0.0 W
Average Power : 0.0 W
Peak Power
: 0.0 W
Max Power : 800.0 W
Remaining Guaranteed Power : 800.0 W
PSE CPLD Version : -
PSE Software Version : 390
PSE Hardware Version : 57603
Legacy PD Detection : Disabled
Power Utilization Threshold : 80