![HPE FlexFabric 5700 Series Скачать руководство пользователя страница 204](http://html.mh-extra.com/html/hpe/flexfabric-5700-series/flexfabric-5700-series_network-management-and-monitoring-configuration-manual_2175950204.webp)
195
You can configure EAA monitor policies by using the CLI or Tcl.
A monitor policy contains the following elements:
•
One event.
•
A minimum of one action.
•
A minimum of one user role.
•
One running time setting.
For more information, see "
Elements in a monitor policy
Event
shows types of events that EAA can monitor.
Table 19 Monitored events
Event type
Description
CLI
CLI event occurs in response to monitored operations performed at the CLI.
For example, a command is entered, a question mark (?) is entered, or the
Tab
key is pressed to complete a command.
Syslog
Syslog event occurs when the information center receives the monitored log
within a specific period.
NOTE:
The log that is generated by the EAA RTM does not trigger the monitor policy to
run.
Process
Process event occurs in response to a state change (caused by an automatic
system task) of the monitored process (such as an exception, shutdown, start,
or restart).
Hotplug
Hotplug event occurs when the following situations occur:
•
Master/subordinate switchover occurs.
•
Member device is added to or removed from the IRF fabric.
Interface
Each interface event is associated with two user-defined thresholds: start and
restart.
An interface event occurs when the monitored interface traffic statistic crosses
the start threshold in the following situations:
•
The statistic crosses the start threshold for the first time.
•
The statistic crosses the start threshold each time after it crosses the
restart threshold.
SNMP
Each SNMP event is associated with two user-defined thresholds: start and
restart.
SNMP event occurs when the monitored MIB variable's value crosses the start
threshold in the following situations:
•
The monitored variable's value crosses the start threshold for the first
time.
•
The monitored variable's value crosses the start threshold each time after
it crosses the restart threshold.
SNMP-Notification
SNMP-Notification event occurs when the monitored MIB variable's value in an
SNMP notification matches the specified condition. For example, the broadcast
traffic rate on an Ethernet interface is equal to or greater than 30%.