Removal and replacement procedures 79
8.
Using an alcohol wipe, remove the existing thermal grease from the processor and heatsink. Allow
the alcohol to evaporate before continuing.
9.
If reusing the heatsink, please follow the
Processor Spare Kit Installation Instructions
to apply
thermal grease to the processor. Use the full contents of the thermal grease syringe. If installing a
new heatsink, the thermal grease is pre-applied.
10.
Install the processor assembly on the heatsink. Align the Pin 1 indicator on the processor to the Pin
1 indicator on the heatsink, and then latch the processor assembly to the heatsink.