2 Site preparation
The BL860c i2 and i4 Server Blades do not have cooling or power systems. Cooling
and power is provided by the c-Class enclosure.
IMPORTANT:
To avoid hardware damage, allow the thermal mass of the product
to equalize to the temperature and humidity of the installation facility after removing
the shipping materials. A minimum of one hour per 10° C (50° F) of temperature
difference between the shipping facility and installation facility is required.
Server blade dimensions and weight
Table 1 Server blade dimensions and weight for the BL860c i2 and i4
value
Dimensions
36.63 cm (14.42 in.)
Height
5.14 cm (2.025 in.)
Width
48.51 cm (19.1 in.)
Depth
Unloaded: 8.6 kg (19 lb)
Weight
Fully loaded: 11.3 kg (25 lb)
Table 2 Blade Link dimensions and weight
Weight
Width
Height
Blade Link type
.5 lb (.22 kg)
51 mm (2 in)
44 mm (1.73 in)
SBL1 (BL860 i2)
BL1 (BL860 i4)
1 lb (.45 kg)
106 mm (4.17 in)
44 mm (1.73 in)
SBL2 (BL870 i2)
BL2 (BL870 i4)
2 lb (.90 kg)
212 mm (8.34 in)
44 mm (1.73 in)
SBL4 (BL890 i2)
BL4 (BL890 i4)
Enclosure information
All six configurations are supported in HPE c7000 and c3000 Enclosures.
For more enclosure information see:
http://www.hpe.com/servers/bladesystem/enclosures
.
Enclosure environmental specifications
NOTE:
This information is for both c3000 and c7000 Enclosures.
Value
Specification
Temperature range
1
10° C to 35° C (50° F to 95° F)
Operating
-30° C to 60° C (-22° F to 140° F)
Non-operating
Wet bulb temperature
28º C (82.4º F)
Operating
7