IMPORTANT: Gas Plumbing Connections: Use only joint compound or Teflon tape that is resistant to all gases. 

Apply 

to all male pipe fittings only- DO NOT use on FLARED fittings. Be sure to tighten every joint securely. 

 

 

 

 

 

 

     FOR YOUR SAFETY READ BEFORE LIGHTING

 

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury, or loss of life. 

A. This appliance has a pilot which must be lighted by hand. When lighting pilot, follow these instructions exactly.

 

B.

 

BEFORE OPERATION smell around the appliance area for gas. See front page- “What to do if smell gas” section. 

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand,      
    don’t try to repair it. Call a qualified technician. Force or attempted repair may cause a fire or explosion. 

 
 

 

 

        LIGHTING INSTRUCTIONS

 

  

1

. STOP! Read the safety information above on this label.

 

2. Depress black knob (Fig. 1) slightly and turn clockwise        to the OFF position.  
3. Wait (5) minutes to clear out any gas. Then smell for gas. 

      

     If you smell gas,

 STOP! 

See front page- “What to do if smell gas” section.  

       

      If you do not smell gas, proceed to next step. 
4. Depress lightly and turn black knob counterclockwise       to the PILOT position. 
5. Locate the pilot- it is inside the blow out box mounted on left side of fire ring when facing  
    front of fire pit (Fig. 2). 
6. Push the knob all the way in- every 10 seconds, apply flame to the blow out box in Fig. 2  

   

     (Pilot burner will not light until all air is bled from lines).   
7. After pilot lights, hold knob in for 20 seconds or until it will stay lit when you release knob. 

    

     IMPORTATNT: If the pilot will not stay lit after several tries, turn the black knob to the  

                 OFF position and call your service technician or gas supplier. 

8. Turn the control knob counterclockwise        from PILOT to the ON position. 
9. Never leave fire pit unattended by an adult.

 

 
              

     

 
 
 
 
 
 
              

              

      

     

 

       

       

      

Fig. 1 

 

 

                                 Fig. 2 

         

        Valve Control Knob              

       Blow Out Box- Pilot Assembly Inside.

 

 

      

 

 

 
 
 
 
 
 
 
 