![HP VMA Series Скачать руководство пользователя страница 200](http://html.mh-extra.com/html/hp/vma-series/vma-series_installation-and-service-manual_159708200.webp)
Appendix C - Alarm Reference
200
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Flash Sequence Number Mismatch Alarm
The Flash Sequence Number Mismatch alarm indicates that the VIMM
sequence numbers in a particular RAID group do not match when data is written
to those VIMMs.
To clear the alarm, update the sequence number on all the VIMMs in the group.
The data on those VIMMs may be corrupt.
Preparing Flash on VIMM Alarm
The Preparing Flash on VIMM alarm indicates that flash is being prepared on the
specified VIMM for use by the system. This alarm clears once the flash
preparations have completed.
VIMM Flash Format In Progress Alarm
The VIMM Flash Format In Progress alarm indicates that the flash VIMMs
formatting is in progress. To begin the flash formatting, the system must be
rebooted first.
The alarm LED flashes.
To clear the alarm:
1.
Wait for the system to successfully complete the boot up process.
2.
Type
show system alarm
to display the percentage of the flash format
progress.
Port Non-Service Affecting Alarms
There are two non-service affecting port alarms.
•
PCIe Cable Plugged Into Disabled Port Alarm
•
Port Is Not Running at the Maximum Data Rate Possible Alarm
PCIe Cable Plugged Into Disabled Port Alarm
The PCIe Cable Plugged Into Disabled Port alarm indicates that the PCIe cable
has been connected to the specified disabled port:
1
or
2
. The Alarm LED is not
lit when this alarm occurs.
To clear the alarm, disconnect the PCIe cable from the disabled port.
Содержание VMA Series
Страница 4: ...4 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 21: ...PART I Product Overview Chapter 1 VMA series Overview Chapter 2 Violin Intelligent Memory Modules ...
Страница 22: ......
Страница 38: ......
Страница 116: ......
Страница 180: ...Appendix A Product Models 180 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 186: ...Appendix B Compliance Information 186 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 208: ...Appendix C Alarm Reference 208 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 300: ...Appendix D CLI Reference 300 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...