![HP VMA Series Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/hp/vma-series/vma-series_installation-and-service-manual_159708094.webp)
Chapter 5 - Operating the System via the CLI
94
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
3.
At the context prompt, type:
The command displays information similar to the following:
Displaying Fan Status
Display the status of the system fans for maintenance and troubleshooting
purposes. The fans are located in two fan trays designated as
1
(top) and
2
(bottom), and the fans are designated as
Left
,
Center
, and
Right
.
To display the current status of the fans:
1.
Log into the Memory Array
2.
Navigate to the desired
Fan
context level. At the root prompt, type:
Where:
3.
At the context prompt, type:
Where:
show vimm-summary
chassis board 0>
show vimm-summary
num-vimms 42
installed-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-69,71,75,76,78-80
flash-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-69,71,75,76,78-80
admin-down-vimm-ids 39
installed-mem-raw 2886.2GB (2688GiB)
usable-mem-raw 2199.0GB (2048GiB)
parity-mem-raw 549.8GB ( 512GiB)
spare-mem-raw 68.7GB ( 64GiB)
unavailable-mem-raw 68.7GB ( 64GiB)
formatted-percentage 78.1%
usable-mem-formatted 1718.0GB (1600GiB)
context chassis fan-tray
{1 | 2}
1
Specifies the top fan tray.
2
Specifies the bottom fan tray.
show fan
{left | center | right}
left
Specifies the left fan in the specified fan tray.
center
Specifies the center fan in the specified fan tray.
right
Specifies the right fan in the specified fan tray.
Содержание VMA Series
Страница 4: ...4 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 21: ...PART I Product Overview Chapter 1 VMA series Overview Chapter 2 Violin Intelligent Memory Modules ...
Страница 22: ......
Страница 38: ......
Страница 116: ......
Страница 180: ...Appendix A Product Models 180 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 186: ...Appendix B Compliance Information 186 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 208: ...Appendix C Alarm Reference 208 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 300: ...Appendix D CLI Reference 300 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...