![HP VMA Series Скачать руководство пользователя страница 234](http://html.mh-extra.com/html/hp/vma-series/vma-series_installation-and-service-manual_159708234.webp)
Appendix D - CLI Reference
234
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Under normal conditions for a fully-populated system, the command displays the
following information:
The following example shows a system that is experiencing errors.
The command lists the following information:
chassis board 0>
show vimm-summary
num-vimms 42
installed-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-
69,71,75,76,78-80
flash-vimm-ids 3-8,12-18,22-27,35,38-45,48,60,64-
69,71,75,76,78-80
admin-down-vimm-ids 39
installed-mem-raw 2886.2GB (2688GiB)
usable-mem-raw 2199.0GB (2048GiB)
parity-mem-raw 549.8GB ( 512GiB)
spare-mem-raw 68.7GB ( 64GiB)
unavailable-mem-raw 68.7GB ( 64GiB)
formatted-percentage 78.1%
usable-mem-formatted 1718.0GB (1600GiB)
chassis board 0>
show vimm-summary
num-vimms 42
installed-vimm-ids 0-41
flash-vimm-ids 0-41
admin-down-vimm-ids 37
installed-mem-raw 1894.1GB (1764GiB)
usable-mem-raw 1443.1GB (1344GiB)
parity-mem-raw 360.8GB ( 336GiB)
spare-mem-raw 90.2GB ( 84GiB)
unavailable-mem-raw 42.2GB
(
40GiB)
formatted-percentage 78.1%
usable-mem-formatted 1126.9GB (1000GiB)
admin-down-vimm-ids 68,72,80
isolated-vimm-ids 76
Table D.7 show vim-summary Command Output Descriptions
Output
Description
num-vimms
Indicates the number of VIMMs physically installed
in the system.
installed-vimm-ids
Indicates the IDs of the VIMMs that are physically
present.
flash-vimm-ids
Indicates the IDs of the flash VIMMs that are
physically present.
admin-down-vimm-
ids
Indicates the IDs of the VIMMs that have been
administratively taken out-of-service through the
user interface.
Содержание VMA Series
Страница 4: ...4 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 21: ...PART I Product Overview Chapter 1 VMA series Overview Chapter 2 Violin Intelligent Memory Modules ...
Страница 22: ......
Страница 38: ......
Страница 116: ......
Страница 180: ...Appendix A Product Models 180 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 186: ...Appendix B Compliance Information 186 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 208: ...Appendix C Alarm Reference 208 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...
Страница 300: ...Appendix D CLI Reference 300 VMA series Memory Array Installation and Service Guide HP AM456 9002A Rev 01 ...