7.2. Pump
In Tumble Dryer models, the pump is used
to transport the water that accumulates in
the condensation chamber to tank in the
drawer area. One triac is measured on the
electronic card.
Technical Features
Resistance : 764±10% ohm
Voltage: 220-240 Volt
Frequency: 50 Hz
Input Power : 13W max
Component Test
Check the connection of the pump connector
Check the pump resistances
Check whether pump is working, by feeding externally
If the pump is working, the water in the tank is unloaded by running the pump Then,
Unload 500 ml of water from water tank to pump reservoir and check whether water is
pumping.
While pump is working, if water is not reached into water tank, hoses should be checked.
Содержание T2touch PANEL
Страница 1: ...HP T2 TOUCHPANEL SERVICE MANUAL SECHE LINGE MANUEL DE SERVICE Bandeau HP T2 Touch ...
Страница 16: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 6 Side Panel 1 Remove 10 screws on side panels ...
Страница 20: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 9 Rear Cover 1 Remove all screws shown in the photo ...
Страница 38: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 24 Plinth Cover 1 Remove 2 plinth pin on Plinth cover ...
Страница 40: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 6 26 Drum Bearing Wheel 1 Remove wheels as shown in the photo ...
Страница 50: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 1 1 Motor Measurements 1 2 3 2 1 3 3 1 2 ...
Страница 52: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1 ...
Страница 56: ...HP T2touch PANEL CUSTOMER SUPPORT SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r ...