10. Verify if the primary controller currently installed has the desired firmware using the front panel
display. The following table shows the proper front panel commands to view which controller is the
primary array controller, and what version of firmware is on the primary array controller.
KEY DISPLAY
CANCEL CANCEL
“Not Enough Disks”
MENU “Language”
– “View
Settings”
ENTER
“System State: Not Enough Disks”
+
“Warning: Firmware Needed”
+
“Primary Cntrl: X”
+
“SCSI ID x: ___”
+
“SCSI ID y: ___”
+ “Firmware:
HP__”
11. Copy the firmware from the primary controller to the secondary controller using the front panel:
KEY DISPLAY
CANCEL CANCEL
“Not Enough Disks”
MENU “Language”
+ “Cntrl
Changes”
ENTER “SCSI
ID”
– “Copy
Firmware”
ENTER “Confirm”
ENTER “Copying
Firmware”,
then “Firmware Loading”,
then array will initialize
then “Offline SCSI ID”
12. The front panel display should say “Not Enough Disks”. Check the “System State” on the front panel
display. It should say “Not Enough Disks” with no other warnings.
KEY DISPLAY
CANCEL CANCEL
“Not Enough Disks”
MENU “Language”
– “View
Settings”
ENTER
“System State: Not Enough Disks”
+
“Primary Cntrl: X”