background image

replacing the disk enclosure power supply,

29

replacing the I/O module,

28

replacing the mezzanine controller,

24

replacing the SAS cable,

28

replacing the SAS switch,

27

replacing the VC Flex-10 module,

26

replacing the VC FlexFabric module,

26

S

SAS cable,

28

SAS switch,

12

27

solution configuration,

5

storage blade

replacement,

21

storage blade disk drive

replacement,

23

replacing both,

23

storage system

repair,

18

Subscriber's Choice, HP,

32

support software, remote,

32

T

technical support

HP,

32

service locator website,

33

troubleshooting

BIOS reset,

14

components,

13

HP 4630 system,

13

specific issues,

14

Turkey RoHS material content declaration,

39

U

Ukraine RoHS material content declaration,

39

upgrading firmware,

20

utility

system backup,

12

V

VC Flex-10 module

bays,

26

configuration backup,

11

replacing,

26

VC FlexFabric

replacing,

26

VC FlexFabric, replacing,

26

Virtual Connect Flex-10 module

backing up configuration,

11

Virtual Connect Manager

for configuration backup,

11

rebuilding SAS switch,

12

W

warning

rack stability,

33

warranty entitlement labels

locations,

14

warranty information

HP Enterprise servers,

39

HP Networking products,

39

HP ProLiant and X86 Servers and Options,

39

HP Storage products,

39

websites

customer self repair,

33

HP ,

33

HP Subscriber's Choice for Business,

32

product manuals,

33

42

Index

Содержание StoreVirtual 4630

Страница 1: ...pairing networked storage For installation and configuration information see the HP StoreVirtual 4630 Storage Quick Start Guide For day to day operations see the HP StoreVirtual Storage User Guide For late breaking information HP recommends that you read the release notes for the installed software version Obtain the latest version of this and other HP StoreVirtual user documents at http www hp co...

Страница 2: ... additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Acknowledgments Microsoft Windows is a U S registered trademark of Microsoft Corporation Warranty To obtain a copy of the warranty for this product see the warranty information website http www hp com go storagewarranty Revision History March 2013 Revision 1 First edition December 2013 Revis...

Страница 3: ...eplacing the HP 4630 system components 20 Additional component removal and replacement instructions 20 Identifying hot pluggable and non hot pluggable components 20 Replacing the storage blade and storage blade components 21 Replacing a storage blade 21 Replacing a storage blade system board 22 Replacing a storage blade disk drive 23 Replacing both storage blade disk drives 23 Replacing the Flexib...

Страница 4: ...A HP 4630 system cabling 35 B Regulatory information 39 Turkey RoHS material content declaration 39 Ukraine RoHS material content declaration 39 Warranty information 39 Glossary 40 Index 41 4 Contents ...

Страница 5: ... NOTE The HP 4630 system only supports the latest c7000 enclosure You can verify the version using Onboard Administrator Log in and select the Information panel in Enclosure Information The Model field should display BladeSystem c7000 Enclosure G2 and the Version field should list firmware version 3 60 or later If the information in these fields does not match what is listed here you are using an ...

Страница 6: ...Figure 1 Front view 2 system configuration 1 Blade enclosure 1 2 Storage blades 2 3 HP BladeSystem Insight Display 1 4 Disk enclosures 2 6 Overview ...

Страница 7: ...Figure 2 Front view 4 system configuration 1 Blade enclosure 1 2 Storage blades 4 3 HP BladeSystem Insight Display 1 4 Disk enclosures 4 Hardware configuration 7 ...

Страница 8: ...Figure 3 Front view 6 system configuration 1 Blade enclosure 1 2 Storage blades 6 3 HP BladeSystem Insight Display 1 4 Disk enclosures 6 8 Overview ...

Страница 9: ...or quick installation and setup see the HP StoreVirtual 4630 Storage Quick Start Guide For links to the latest manuals for HP BladeSystem and other components go to http h18004 www1 hp com products blades components c class tech installing html For detailed instructions about using the HP 4630 storage system see the following resources Documentation available 9 ...

Страница 10: ...le HP StoreVirtual Storage Remote Copy User Guide Find information about configuring and using asynchronous replication of storage volumes and snapshots across geographic distances HP StoreVirtual Storage Multi Site Configuration Guide Find detailed instructions for designing and implementing the Multi Site SAN features to synchronously and automatically mirror data between geographic sites HP Sto...

Страница 11: ...kup configurations created with previous versions of Virtual Connect Manager For example if you are currently using 2 01 you cannot use a backup configuration that was created using 1 20 1 From Onboard Administrator go to the Virtual Connect Manager Domain Settings Backup Restore pane 2 Click Backup Configuration 3 Click Save on File Download in the popup window 4 Navigate to the hard drive locati...

Страница 12: ... the other switch If you are replacing both SAS switches you must restore the configuration from a backup captured using the VSM CLI For information about backing up and restoring the SAS configuration using the VSM CLI see the HP Virtual SAS Manager User Guide IMPORTANT HP recommends that you do not change the SAS zoning on the SAS switches or the cabling between the SAS switches and the disk enc...

Страница 13: ... ProLiant Gen8 Servers tab the User Guide is located in the General Reference section HP Smart Array Controllers for HP ProLiant Servers User Guide HP Smart Array P721m controller http h18004 www1 hp com products blades components c class tech installing html On the Installing tab scroll to the 6G Blade SAS External Storage Solution table and HP 6Gb SAS BL Switch User Guide HP 6Gb SAS BL switch se...

Страница 14: ...system warranty entitlement labels You must locate and identify the serial number on the HP 4630 system components to obtain service under the warranty If the storage blade is powered on and accessible from the CMC select Diagnostics and go to the Hardware information panel The part number serial number and entitlement order number are displayed under the warranty information section A warranty en...

Страница 15: ...e MAC address Complete the following steps 1 Log into iLO for the storage blade 2 Navigate to the System Information Network tab to obtain the eth0 Port 1 MAC address 3 Copy the MAC address for future use Request the license key The easiest way to enter the license key into the HP 4630 system is by using a USB flash drive You may also enter in the license key if you do not have a USB flash drive 1...

Страница 16: ...on the storage blade 27 hard drives which include the following Type and number of drives Slot 2 25 drives on the HP Smart Array P721m controller Slot 0 2 drives on the HP Smart Array P220i controller 64 GB Memory HP FlexFabric 10Gb 2 port 554FLB Adapter appears as OneConnect 10Gb NIC be3 in the CMC NIC 9 From the Categories list select Storage 10 Verify that the specified item meets the minimum r...

Страница 17: ...e NOTE Use the iLO dongle delivered with the c7000 enclosure to connect the USB flash drive so that you can plug in the USB key 4 When prompted to identify the OS version to install enter Y IMPORTANT Manually entering the license key If the installer program cannot find a properly formatted license key on the USB flash drive you will be given the chance to enter in the license key Enter the licens...

Страница 18: ...lacement involves two rebuilds IMPORTANT The hot spare may take up to 30 seconds to transition to the rebuilding state Confirm drive status in the CMC before removing any drives If more than one disk fails or is removed without breaking a RAID set the hot spare begins rebuilding one of the failed or removed disks When multiple failed disks are replaced the P721m controller attempts to restore the ...

Страница 19: ...the firmware of each component located in the individual component product user guides For more information see the component guides listed in Additional component removal and replacement instructions page 20 The following operations will take a volume offline unless the volume and management group or cluster are configured for high availability Upgrading the controller firmware All controllers mu...

Страница 20: ... Switch for HP BladeSystem c Class Replacement Instructions HP 6G SAS BL Switch Storage Solution table and select the PDF link in the Customer Self Repair column for the HP 6Gb SAS BL Switch row http www hp com go proliantgen8 docs On the HP ProLiant Gen8 Servers tab the User Guide is located in the General Reference section HP Smart Array Controllers for HP ProLiant Servers User Guide HP Smart Ar...

Страница 21: ...more detailed instructions on replacing the storage blade or storage blade components see Table 4 page 20 for resources To initiate OS recovery 1 Connect to the storage blade using iLO or the USB dongle connected to the storage blade On the console enter start at the prompt and then log in 2 Select Support Operations 3 Select Initiate OS Recovery On the screen that displays select OK to confirm th...

Страница 22: ...oning Replacing a storage blade system board Prepare the system board for replacement NOTE The following steps can only be performed if the storage blade is bootable and accessible from the CMC If the storage blade does not boot skip these steps and go to Replace the system board 1 Confirm the RAID and customer data Ensure that RAID is configured on the old blade and that the customer data exists ...

Страница 23: ...al SFF disk drives in the storage blade As long as one drive continues to operate the storage blade can operate You do not need to power down the storage blade you can hot swap disk drives However you must replace the removed drive with a drive of the same size or larger To replace a disk drive in the storage blade 1 Verify the disk drive has failed as follows The drive failure LED is lit The Alar...

Страница 24: ...ng the CMC The link status shows it is off 2 Power down the storage blade 3 Remove the storage blade from the blade enclosure 4 Remove the top cover from the storage blade 5 Disconnect the capacitor module cable and remove the P721m controller 6 Remove the FlexibleLOM module 7 Install the replacement FlexibleLOM module 8 Reinstall the P721m controller and reconnect the capacitor module cable 9 Rei...

Страница 25: ...r the blade to power down This procedure flushes all data from the cache CAUTION Since the HP 4630 storage system uses external data storage ensure that the storage blade is the first unit to be powered down and the last to be powered up This precaution ensures that the system does not mark the drives as failed when the storage blade is powered up 3 Remove the storage blade from the blade enclosur...

Страница 26: ...blade to power down This procedure flushes all data from the cache CAUTION Since the HP 4630 storage system uses external data storage make sure that the storage blade is the first unit to be powered down and the last to be powered up This precaution ensures that the system does not mark the drives as failed when the storage blade is powered up 3 Remove the storage blade from the blade enclosure 4...

Страница 27: ...This preference remains in place until the controllers in the blade enclosure are power cycled or the remaining path becomes unavailable To replace the SAS switch 1 Log in to the Onboard Administrator and identify the SAS switch that has failed 2 Power down the storage blades 3 Power down the SAS switch from the Onboard Administrator NOTE When a switch is powered down the following message display...

Страница 28: ...e storage blade using the CMC Select storage system in the management group and select either the Power off or Reboot option to shut down the storage blade 2 Manually power off the D2700 disk enclosures 3 Replace the SAS cable 4 Using the HP Virtual SAS Manager verify the status of the disk enclosures and zones 5 Power on the storage blade See HP 4630 system cabling page 35 for an illustration of ...

Страница 29: ...es and zones Ensure that both I O modules are running the same firmware version If not upgrade the firmware to the latest version Verify that the zone is properly assigned to correct blade bay 9 Power on the storage blade Log in to the CMC and verify that the RAID status is Normal Replacing the disk enclosure power supply There are two power supplies in each disk enclosure chassis The system can o...

Страница 30: ... Generate the support bundle using the CMC Right click the storage system and select Export Storage System Support Bundle 4 Remove the failed drive 5 Insert the replacement drive When replacing a drive ensure that the drive capacity is the same or greater than the other drives in the disk enclosure Installing a lower capacity drive will prevent the RAID controller from rebuilding Also ensure the d...

Страница 31: ...storage blade 9 Power on the storage blade The RAID controller imports the RAID configuration from the drives and LeftHand OS metadata mounts properly Store and manager processes start properly using the LeftHand OS metadata The storage systems displays in the management group and volumes begin resynchronizing NOTE If either of the following issues occur you must use the Repair Storage System feat...

Страница 32: ...s and automatic secure submission of hardware event notifications to HP which will initiate a fast and accurate resolution based on your product s service level Notifications may be sent to your authorized HP Channel Partner for on site service if configured and available in your country The software is available in two variants HP Insight Remote Support Standard This software supports server and ...

Страница 33: ...ng HP ships the part directly to you so that you can install it at your convenience Some parts do not qualify for CSR Your HP authorized service provider will determine whether a repair can be accomplished by CSR For more information about CSR contact your local service provider or see the CSR website http www hp com go selfrepair Replaceable parts This product contains replaceable parts To identi...

Страница 34: ...ice provided for this product see the warranty information website http www hp com go storagewarranty To order a replacement part contact an HP authorized service provider or see the HP Parts Store online http www hp com buy parts 34 Support and other resources ...

Страница 35: ...em SAS cabling is shown in Figure 9 page 35 through Figure 12 page 38 Figure 9 2 system cabling 1 HP VC Flex 10 or HP VC FlexFabric modules 2 2 HP 6Gb SAS BL switches 2 3 HP ProLiant Onboard Administrator 4 Disk enclosure power on buttons 2 35 ...

Страница 36: ...Figure 10 4 system cabling 1 HP VC Flex 10 or HP VC FlexFabric modules 2 2 HP 6Gb SAS BL switches 2 3 HP ProLiant Onboard Administrator 4 Disk enclosure power on buttons 4 36 HP 4630 system cabling ...

Страница 37: ...Figure 1 1 6 system cabling 1 HP VC Flex 10 or HP VC FlexFabric modules 2 2 HP 6Gb SAS BL switches 2 3 HP ProLiant Onboard Administrator 4 Disk enclosure power on buttons 6 37 ...

Страница 38: ...Figure 12 8 system cabling 1 HP VC Flex 10 or HP VC FlexFabric modules 2 2 HP 6Gb SAS BL switches 2 3 HP ProLiant Onboard Administrator 4 Disk enclosure power on buttons 8 38 HP 4630 system cabling ...

Страница 39: ...бладнання відповідає вимогам Технічного регламенту щодо обмеження використання деяких небезпечних речовин в електричному та електронному обладнанні затвердженого постановою Кабінету Міністрів України від 3 грудня 2008 1057 Warranty information HP ProLiant and X86 Servers and Options http www hp com support ProLiantServers Warranties HP Enterprise Servers http www hp com support EnterpriseServers W...

Страница 40: ...e FCC Federal Communications Commission FOM Failover Manager iLO 2 HP Integrated Lights Out 2 iSCSI Internet SCSI KVM Keyboard video mouse switch LUN Logical unit number NIC Network interface card OA Onboard Administrator POST Power on self test RBSU ROM based setup utility RF Radio frequency SAN Storage Area Network SAS Serial Attached SCSI SFF Small Form Factor SSH Secure Shell UPS Uninterruptib...

Страница 41: ...irmware upgrades 19 firmware upgrade 20 Flex 10 module replacing 26 Flex 10 module replacing 26 H hard drive disk enclosure 30 help obtaining 32 HP technical support 32 I I O module replacing 28 Insight Remote Support software 32 M maintenance HP 4630 system 13 warranty entitlement labels 14 mezzanine controller battery 24 replacing 24 mezzanine controller replacing 24 O offline volumes 19 overvie...

Страница 42: ...nts 13 HP 4630 system 13 specific issues 14 Turkey RoHS material content declaration 39 U Ukraine RoHS material content declaration 39 upgrading firmware 20 utility system backup 12 V VC Flex 10 module bays 26 configuration backup 1 1 replacing 26 VC FlexFabric replacing 26 VC FlexFabric replacing 26 Virtual Connect Flex 10 module backing up configuration 1 1 Virtual Connect Manager for configurat...

Отзывы: