![HP StoreOnce D2D Backup System Gen2E Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/hp/storeonce-d2d-backup-system-gen2e/storeonce-d2d-backup-system-gen2e_maintenance-and-service-manual_2175316021.webp)
1.
Power off the HP D2D Backup System. Remove the cover from the HP D2D, as described in
the appropriate HP ProLiant Maintenance and Service guide, and locate the P411 controllers
in PCI-e slots 5 and 6.
NOTE:
The LEDs on the P411 controller card provide diagnostic information when the unit
is powered on. For a detailed description of these LEDs, refer to the “HP Smart Arrays for HP
ProLiant Servers user guide”.
2.
Unclip the blue PCIe card retaining latch and remove the PCIe card.
3.
Install the new P411 card and check that it is seated properly. Close the blue PCIe card
retaining latch.
4.
Replace the cover, as described in the appropriate HP ProLiant Maintenance and Service
guide, and power on the HP D2D Backup System.
5.
Install the SAAP license.
a.
Reboot the system.
b.
During the POST screen, when advised, hit any key to see further messages.
c.
Enter the Smart Array POST ORCA utility by pressing [F8] when details for the P411 card
are displayed during the POST messages.
d.
Select the
Manage Licenses
option in the Smart Array menu, and then select
Install Licenses
.
e.
Enter the licence key previously noted.
HP SAS expander card (HP D2D4312)
If no disks are showing on the Storage-Shelves page of the D2D Web Management Interface, there
may be a problem with the HP SAS expander card.
The part number for a replacement card is: 468405–001. It must be installed in PCI-e slot 1.
Mini-SAS cables (part numbers 493228–005 and 493228–006) connect the expander card to
the hard disk drive backplane, as described in the following table. SAS cables are also connected
from the motherboard to the SAS expander card
NOTE:
Tuck the mini-SAS cables to be routed to the backplane into the side of the chassis. Loop
the SAS cables to connect to the motherboard in the void.
Table 5 Cabling to HP SAS expander card (HP D2D4312)
To
From.
Connect
Bottom right HDD backplane
connector
Port 2C on SAS expander card
493228–006 mini-SAS cable
1
Top right HDD backplane connector
Port 3C on SAS expander card
493228–006 mini-SAS cable
2
Bottom left HDD backplane
connector
Port 4C on SAS expander card
493228–005 mini-SAS cable
3
Top left HDD backplane connector
Port 5C on SAS expander card
493228–005 mini-SAS cable
4
Port 8C on the SAS expander card
Connector A (left) on the
motherboard
SAS cable
5
Port 9C on the SAS expander card
Connector B (right) on the
motherboard
SAS cable
6
HP SAS expander card (HP D2D4312)
21