Storage server Web User Interface
Issue:
Error while creating an NFS-shared folder
Description
If you create a folder on the storage server and enable NFS sharing for the folder,
an NTFS File ID is created. If that folder is deleted and a new folder is created
using the same name, NFS sharing is automatically enabled using the same NFS
settings as the original folder.
Workaround
Try not to reuse folder names. If the same folder name is necessary, the NFS
client needs to remount the NFS share.
Issue:
Extend function may show an available disk space value greater than the amount of space
that a disk volume can grow
Description
The extend function within the WebUI does not recognize extended disk volume
partition boundaries. As such, if an extended partition is created that consumes
part of a disk and the extended partition has a logical drive that consumes a
portion of the extended partition, the WebUI may report that all available disk
space on that disk is usable for extending the logical drive within the extended
partition.
Workaround
Because extended partitions are seen as virtual physical disks, the logical drive
within the extended partition can only be extended to the size of the extended
partition. Primary partitions and dynamic disks are not affected by this issue.
Issue:
Secure Path Manager displays
Unable to complete your request
error window
Description
Accessing Secure Path Manager through the WebUI Secure Path Manager page
may return an
Unable to complete your request due to added
security features
error dialog box and a Security Alert dialog box. These
dialog boxes are benign and are caused by the WebUI pointing to Secure Path
Manager unsecured HTTP port 2301 instead of the required Secure Path Manager
secured HTTPS port 2381.
Workaround
Click
Yes
on the
Security Alert
dialog box to display the HP Insight Manager/Secure
Path Manager login page at port 2381. Log in and access Secure Path Manager.
Issue:
Rapid startup wizard does not function if a network interface has not been enabled
Description
Rapid startup wizard does not function if a network interface has not been enabled.
Workaround
Before using the rapid startup wizard in the WebUI, ensure that at least one
network interface has been enabled.
Issue:
In Storage Reports, the Japanese folder names are not displayed correctly
Description
This issue appears in the folder name displayed on the tool tip of the pie chart
version of the storage report.
Workaround
HP engineers are working to resolve this issue.
Issue:
Enable boot
fl
oppy feature in the WebUI does not work
Description
The enable boot
fl
oppy feature in the WebUI does not work.
Workaround
If a
fl
oppy boot is required, use the ROM-Based Setup Utility (press
F9
during
system boot) to enable the
fl
oppy on boot.
Issue:
WebUI pages have errors when logged in as a domain administrator
14
Содержание StorageWorks X5000