![HP StorageWorks 8B - FC Entry Switch Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/hp/storageworks-8b-fc-entry-switch/storageworks-8b-fc-entry-switch_installation-manual_164017098.webp)
Technical Specifications
98
SAN Switch 2/8 Version 3.1.x Installation Guide
Serial Port Specifications
The Serial port can be used to connect to a computer workstation to configure the
switch IP address without connecting to the fabric. The Serial port’s parameters
are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
The port requires a straight Serial cable with a female 9-pin subminiature-D
connector. Only pins 2, 3, and 5 are supported; if pin 7 is used, the signal must
always be driven high, using the pinouts listed in
Table 9
.
Note:
For dust and ESD (electrostatic discharge) protection, a cover is provided for the
Serial port and should be kept on the port whenever the Serial port is not in use.
Table 9: Cabling Pinouts if Pin 7 is Used
PIN
Signal
Description
1
2
TxData
Transmit Data
3
RxData
Receive Data
4
5
GND
Logic Ground
6
7
CTS
Clear to Send
8
9