![HP StorageWorks 8B - FC Entry Switch Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/hp/storageworks-8b-fc-entry-switch/storageworks-8b-fc-entry-switch_installation-manual_164017063.webp)
Installing the SAN Switch 2/8
63
SAN Switch 2/8 Version 3.1.x Installation Guide
Modifying Domain IDs
Optional. Modify the domain IDs if desired, as follows.
Note:
It is best to assign a unique domain ID prior to connecting the switch to other
switches in the SAN. This eliminates the possibility of domain ID overlap.The default
domain ID is 1. If the default domain ID is already in use when the switch is connected
to the fabric, the domain ID for the new switch is automatically reset to a unique value.
The domain IDs that are currently in use can be determined using the telnet command,
fabricShow
.
1. To disable the switch, type:
switchDisable
2. Enter the following:
configure
3. Enter
y
after the Fabric Parameters prompt.
Fabric parameters (y, n)
4. Enter a unique domain ID (such as the domain ID used by the previous
switch, if still available).
Domain: (1..239) [1] 3
5. Complete the remaining prompts (or press CTRL+D to accept the remaining
settings without completing all the prompts).
6. To re-enable the switch, type:
switchEnable