Workaround prior to upgrade:
After
enabling FMSMODE for the first time,
do
switchdisable
/
switchenable
-
hafailover
-
hareboot
-
reboot
.
Fixed in Fabric OS 6.2.0d
CP panicked with FICUD crash and rebooted during
supportsave
.
Fixed in Fabric OS 6.2.0d
If ISL links between two encryption cluster nodes are continuously dis-
connected/reconnected during rekey operations, one of the LUNs can
hang at
LUN discovery
state.
Fixed in Fabric OS 6.2.0d
LUNs in a container show target offline, leading to the host no longer
having access to their LUNs through the crypto target containers.
Fixed in Fabric OS 6.2.0d
With tape pipelining active, the switch may return a good status without
sending data, leading to tape I/O failure/errors.
Fixed in Fabric OS 6.2.0d
The host detects IFCC errors to CUP port.
Fixed in Fabric OS 6.2.0d
HP StorageWorks Encryption SAN Switch went faulty when starting
traffic, which let to loss of LUNs to the host.
Fixed in Fabric OS 6.2.0d
Taking SKM down while rekeys are in progress causes a LUN to get
stuck in
Not ready (Key creation)
state.
Fixed in Fabric OS 6.2.0d
When attempting to swap ports from the Web Tools GUI, the operation
may fail due to an HTTP 500 error.
Fixed in Fabric OS 6.2.0d
Default SNMP v3 values set differently in different Fabric OS releases
leading to the
mibcapability
option of
snmpconfig
not being
able to control ficon mib.
Fixed in Fabric OS 6.2.0d
In Access Gateway mode, if the second FDISC comes in before the
switch responds to the first FDISC between the same pair of devices,
the Access Gateway panics, triggering a reboot.
Two new FRU classes have been
created in Fabric OS 6.2.0d
(
coreblade
and
applicationblade
).
Applications cannot distinguish between application blade and Core
blades using SNMP.
Two more values for SNMP port
status:
validating (10)
[module
is being validated] and
invalidModule (11)
[module is
invalid] have been added to Fabric
OS 6.2.0d
SNMP object
swFCPortPhyState
gets invalid value 11.
Fixed in Fabric OS 6.2.0d
Web Tools reports certain devices incorrectly due to a WWN mapping
issue.
Fixed in Fabric OS 6.2.0d
Memory usage for weblinker gets very high when DCFM is polling
LUNs.
Fixed in Fabric OS 6.2.0d
With Virtual Fabrics, deleting a FID while in the FID leads to the user
being stuck in the FID, and all commands generating an error message.
HP StorageWorks Fabric OS 6.2.0g release notes
49