Workaround prior to upgrade:
Activate the same PDCM Matrix from
Web Tools with
Active=Save
Mode
check from
Edit CUP Port
Connectivity configuration
window.
Fixed in Fabric OS 6.2.0b.
When activating a saved PDCM Matrix from
activate CUP Port
Connectivity Configuration
dialog in Web Tools, with
Act-
ive=Save Mode
checked, Web Tools displays an error.
Workaround prior to upgrade:
The
switch name can be displayed from
Fabric OS CLI command
switchname
Fixed in Fabric OS 6.2.0b.
c-Class Onboard Administrator is unable to read the
switchname
for Brocade 8Gb SAN Switch for HP BladeSystem c-Class.
Workaround prior to upgrade:
Stop
and restart I/O may recover.
Fixed in Fabric OS 6.2.0b.
End-to-end data frames in one direction of bidirectional I/O not re-
covered after
switchdisable
and
switchenable
on a Base switch.
Fixed in Fabric OS 6.2.0b.
Unexpected software call traceback error messages occasionally being
displayed on DC04 console.
Fixed in Fabric OS 6.2.0b.
Frame drops sometimes occur when a trunk port comes online, even
with Lossless DLS feature enabled.
Fixed in Fabric OS 6.2.0b.
Interactive mode stores
supportsave
files in switch root directory
rather than the USB device, which can also result in compact flash
storage overflow.
Fabric OS 6.2.0c fixes
The following table lists defects closed in the Fabric OS 6.2.0c firmware release.
Table 11 Fabric OS 6.2.0c closed defects
Solution
Closed defect summary
Workaround prior to upgrade:
Lock
the switch port to 8 Gb, rather than
rely on auto-negotiation.
Fixed in Fabric OS 6.2.0c
When port locked as G_Port, 8–Gb device may connect at 4 Gb rather
than 8 Gb.
Fixed in Fabric OS 6.2.0c
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when FCR routes are being processed, which results
in missing FCR routes and an inability to route traffic across VEX ports.
This leads to I/O running through VEX ports to be dropped after firm-
ware upgrade.
Fixed in Fabric OS 6.2.0c
VI to PT routes are deleted following
portdisable
/
portenable
on HP StorageWorks SAN Director 48 Port FC blade.
Fixed in Fabric OS 6.2.0c
RSCN transmitted by the switch did not transmit all the port IDs in the
payload after HPF key on or off.
46