Specifications
Weight
(approximate)
All hard drives, power
supplies, and processors
installed
37.00 lb (16.78 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
7.31A at 115VAC,
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator
%20Catalog.xls
- Click on the system of interest. Example: DL380 G5
- Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State Power
653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with
an altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 86°F
(30°C).
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr
(20°C/hr).
Relative Humidity
(non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Operating
10,000 ft (3050 m). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
1500 ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457
m/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment. Noise
emissions were measured in accordance with ISO 7779 (ECMA 74) and
declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.86
LpAm
52.36dBA
Operating
LWAd
6.89
LpAm
52.60dBA
QuickSpecs
HP StorageWorks 400t and 400r All-in-One
Storage Systems
Technical Specifications
DA - 12913 Worldwide QuickSpecs — Version 1 — 2.11.2008
Page 20