Diagnostics
58
A faulty power LED is indicated, but director and Fibre Channel port operation is
not disrupted. The LED is connected to the circuitry in a fan module, and the
module must be removed and replaced (“
page 250). Exit MAP.
30
Is the system error LED (amber) at the director front bezel blinking?
YES
NO
↓
31
Unit beaconing is enabled for the director.
1. Consult the customer and next level of support to determine the reason unit
beaconing is enabled.
2. Disable unit beaconing.
a.
At the Hardware View, right-click the front bezel graphic (away from a
FRU). A menu displays.
b. Click Enable Unit Beaconing. The check mark disappears from the box
adjacent to the option, and unit beaconing is disabled.
Was unit beaconing enabled because a director failure or degradation was
suspected?
YES
NO
↓
The director is operational. Exit MAP.
32
Is the system error LED (amber) at the director front bezel illuminated?
YES
NO
↓
The director is operational. Verify operation at the HAFM appliance.
Go to
33
Check FRUs (UPM cards, CTP cards, SBAR assemblies, power supplies, and fan
modules) for failure symptoms.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...