30
HP Scitex Industrial Presses Essential Health and Safety Instructions
Figure 1-14 FB7600 Recommended Power Connection
R1
R1
R2
R2
S1
S1
S2
S2
T1
T1
T2
T2
N
N
N
N
Power
Line
diameters
000(3/0)
AWG
Power
Line
diameters
6 AWG
Power
Line
diameters
1/0 AWG
R
S
T
N
G
Machine
Fuses
3 x 40 A
UV PDU
Fuses
3 x 160 A
Electrical Power Network
3 x 400 VAC + N + G, 50Hz
UV
Electrical
Cabinet
Electrical Cabinet
(PDU)
L
N
G
The indicated currents and wire diameters are the HP-recommended ratings for circuit breakers.
For actual power usage values, refer to Power Requirement tables.
To determine the suitable circuit breaker and fuse ratings for your site, you must consult your local
authorized electrician.
Recommended standard fuse types: A Type or B Type gG Curve
*
All cables for main, machine and UV inline should be supplied by the customer.
Power line length and diameters should be calculated according to the system final position from
the electric supply line.
**
Machine
BLSC
Cabinet
Power Outlet for
White Ink System (optional)
1-Phase,
90 - 264 VAC,
47 - 63 Hz