instructions, review the document titled Installation Guide, Mid-Weight Slide Kit, 5065-7291. This
document can be accessed in the HP website at
http://www.hp.com/racksolutions
WARNING!
Ensure that all anti-tip features are employed before extending the server (front
and rear ant-itip feet installed; adequate ballast is properly placed; and so on).
Extend the Server From the Rack
NOTE:
Ensure that there is approximately 1.5 meters [4.5 ft] in front of the rack to fully extend
the server from the rack.
To extend the server from the rack, follow these steps:
1.
Remove the 25-mm Torx screws that fasten the server to the rack.
Figure 6-1 Accessing T-25 Screws
2.
Flip out the two pull handles at either end of the front bezel and slowly pull the unit forward
by the handles. The server is fully extended when the rail clips are locked in place. When
fully extended, the front and top covers are fully accessible.
Inserting the Server Into the Rack
To insert the server into the rack, follow these steps:
1.
Press the rail clips on either side of the server inward and push the server into the rack until
it stops.
2.
Replace the T-25 screws that fasten the server to the rack.
150
Removing and Replacing Components