RBSU menu (HP ProLiant G6 servers or server blades) 14
For more information on Advanced Memory Protection, see the HP website
(
http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html
).
USB Options (G6 servers)
•
USB Control (G6 servers) (on page
14
)
•
USB 2.0 EHCI Controller (G6 servers) (on page
16
)
•
Removable Flash Media Boot Sequence (G6 servers) (on page
17
)
USB Control (G6 servers)
The USB Control menu determines how USB ports and embedded devices operate at startup:
•
When USB Enabled is selected, all USB ports and embedded devices are enabled.
•
When USB Disabled is selected, all USB ports and embedded devices are disabled.
•
When Legacy USB Disabled is selected, all USB ports are enabled under a USB-aware OS, but USB
is not supported during POST or RBSU. Legacy USB Disabled also disables iLO 2 virtual devices.