background image

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).

Acoustic Noise

Acoustic Noise

Acoustic Noise

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).

Idle

Idle

Idle

Idle

 

   L

WAd

6.86

   L

pAm

52.36dBA

Operating

Operating

Operating

Operating

 

   L

WAd

6.89

   L

pAm

52.60dBA

Emissions Classification

Emissions Classification

Emissions Classification

Emissions Classification
(EMC)

(EMC)

(EMC)

(EMC)

FCC Rating

Class A

Normative Standards

CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1

NOTE:

NOTE:

NOTE:

NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and
statements.

NC362i Integrated Dual

NC362i Integrated Dual

NC362i Integrated Dual

NC362i Integrated Dual
Port Gigabit Server

Port Gigabit Server

Port Gigabit Server

Port Gigabit Server
Adapter

Adapter

Adapter

Adapter

Network Interface

Network Interface

Network Interface

Network Interface

Integrated 10/100/1000BASE-T Transceiver
Combines a triple-speed IEEE 802.3TM - Compliant Media Access
Controller (MAC) with a triple-speed Ethernet transceiver.

Data Transfer Method

Data Transfer Method

Data Transfer Method

Data Transfer Method

Compliant to x1 PCIe Specification

Controller

Controller

Controller

Controller

Intel® 82576

Network Transfer Rate

Network Transfer Rate

Network Transfer Rate

Network Transfer Rate

10Base-T (Half-Duplex)

10 Mb/s

10Base-T (Full-Duplex)

20 Mb/s

100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex) 200 Mb/s
1000Base-TX (Half and
Full-Duplex)

2000Mb/s

Connector

Connector

Connector

Connector

RJ-45 connector

Cable Support

Cable Support

Cable Support

Cable Support

Performs all the physical layer functions for 10BASE-T, 100BASE-T, and
1000BASE-T Ethemet on standard Category 5 UTP

QuickSpecs

HP ProLiant SL160z Generation 6 (G6)

HP ProLiant SL160z Generation 6 (G6)

HP ProLiant SL160z Generation 6 (G6)

HP ProLiant SL160z Generation 6 (G6)

Technical Specifications

DA - 13385   North America — Version 18 — February 13, 2012

Page 41

Содержание ProLiant SL160z - G6 Server

Страница 1: ...arge amounts of memory and I O expansion Open View Open View Open View Open View Rear View Rear View Rear View Rear View 1 18 DDRs DIMM slots 1 Serial Port 2 Up to two Intel Quad Core 5500 sequence processors 2 Video Port 3 Two 3 5 non hot plug hard drives using a quick release drive carrier 3 2 USB Ports 4 2 1Gbit NIC 5 Optional Dedicated Management port 6 UID 7 Optional low profile x16 PCI e Gen...

Страница 2: ...66 HT Turbo 1 1 2 2 Intel Xeon Processor E5520 2 26 GHz 8MB L3 Cache 80W DDR3 1066 HT Turbo 1 1 2 2 Intel Xeon Processor E5506 2 13 GHz 4MB L3 Cache 80W DDR3 800 Intel Xeon Processor E5504 2 00 GHz 4MB L3 Cache 80W DDR3 800 Intel Xeon Processor L5530 2 40 GHz 8MB L3 Cache 60W DDR3 1066 HT Turbo 1 1 2 2 Intel Xeon Processor L5520 2 26 GHz 8MB L3 Cache 60W DDR3 1066 HT Turbo 1 1 2 2 Intel Xeon Proce...

Страница 3: ...ation on ProLiant Energy Efficient Features see www hp com go proliant energy efficient Network Controller Network Controller Network Controller Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter Expansion Slots Expansion Slots Expansion Slots Expansion Slots NOTE NOTE NOTE NOTE Up to two available PCI Express 2 0 slots Optional Slot 1 low profile x16 PCI Express 2 0 and Opti...

Страница 4: ...None standard Drive Bays Up to 2 Non hot plug SATA or SAS 3 5 drives Up to 4 Non hot plug SATA SAS or SSD 2 5 drives requires SFF drive cage Maximum Internal Maximum Internal Maximum Internal Maximum Internal Storage Storage Storage Storage Non Hot Plug SATA 3 5 4 0TB 2 x 2TB Non Hot Plug SATA 2 5 2 0TB 4 x 500GB Non Hot Plug SAS 3 5 4 0TB 2 x 2TB Non Hot Plug SAS 2 5 2 4TB 4 x 600GB Non Hot Plug ...

Страница 5: ...out degrading performance of the ProLiant server Power Supplies have efficiency ratings up to 94 There are five right size power options to choose from depending on the configuration of your server To make sure you select the correct power supply to meet your configuration please use the HP Power Advisor at www hp com go hppoweradvisor All HP Common Slot power sources are UL CE Mark Compliant Hot ...

Страница 6: ... G6 Chassis 2U Chassis NOTE NOTE NOTE NOTE Can support two SL160z server trays in the 2U chassis HP ProLiant SL160z G6 Server 1U server tray Embedded Manageability Embedded Manageability Embedded Manageability Embedded Manageability HP LO100 Advanced HP LO100 Advanced HP LO100 Advanced HP LO100 Advanced HP Lights Out 100 with Optional LO100 Advanced Licenses for Virtual KVM and Virtual Media Stand...

Страница 7: ... repairs may be accomplished through the use of Customer Self Repair CSR parts These parts fall into two categories 1 Mandatory CSR parts are designed for easy replacement A travel and labor charge will result when customers decline to replace a Mandatory CSR part 2 Optional CSR parts are also designed for easy replacement but may involve added complexity Customers may choose to have HP replace Op...

Страница 8: ...n HP across multiple operating system platforms For additional information please see http www hp com go insight Insight Management Agents HP Insight Management Agents and Insight Management Providers are available for HP Systems Insight Manager SIM Integration ProLiant 100 series G6 servers can use the same SNMP based Insight Management Agents supported by other ProLiant servers As a result admin...

Страница 9: ...iber s Choice Driver and Support Alerts Notifications is a web based email subscription service that provides software and driver change notifications for ProLiant products Sign up at http www hp com go subscriberschoice and customize your profile to receive various new alerts as they become available on a weekly or monthly basis ROMPaq software and latest drivers The latest software drivers and f...

Страница 10: ... HP Shmem library as well as the execution environments for the libraries and compiler HP HPC Linux Value Pack Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio for Servers and Storage for Servers and Storage for Servers and Storage for Servers and Storage HP Factory Express offers configuration customization integration and deployment services...

Страница 11: ...buy easy to use scalable support packages for servers storage networking and software Optimized Care Optimized Care Optimized Care Optimized Care Optimized Care Package Supports maintaining servers at optimum performance availability Optimized Care Package Supports maintaining servers at optimum performance availability Optimized Care Package Supports maintaining servers at optimum performance ava...

Страница 12: ... Microsoft or Linux or VMware education courses 60 Proactive Select Credits Basic Care Basic Care Basic Care Basic Care Basic Care Package delivers minimum recommended support service level Basic Care Package delivers minimum recommended support service level Basic Care Package delivers minimum recommended support service level Basic Care Package delivers minimum recommended support service level ...

Страница 13: ...nd service agreement customers For more information For more information For more information For more information To learn more on HP ProLiant servers and HP BladeSystem servers please contact your HP sales representative or HP Authorized Channel Partner Or visit http www hp com services proliant QuickSpecs HP ProLiant SL160z Generation 6 G6 HP ProLiant SL160z Generation 6 G6 HP ProLiant SL160z G...

Страница 14: ...t Gold Hot Plug Power Supply Kit 503296 B21 HP 460W Common Slot Platinum Hot Plug Power Supply Kit 593188 B21 HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327 B21 HP 750W Common Slot Platinum Hot Plug Power Supply Kit 593831 B21 HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172 B21 HP 1200W Common Slot Platinum Hot Plug Power Supply Kit 578322 B21 Step 2 Choose Required Server ...

Страница 15: ...w Voltage DIMMs can only be used with Intel Xeon processor 5600 series processors 604506 B21 HP 16GB 1x16GB Quad Rank x4 PC3 8500 DDR3 1066 Registered CAS 7 Memory Kit 500666 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 LP Memory Kit 627812 B21 Unbuffered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMM...

Страница 16: ... HP P410 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P410 controller 583997 B21 NOTE NOTE NOTE NOTE HP z6000 BBWC HDWR KIT is required when adding BBWC 582653 B21 491195 B21 HP Smart Array P411 256 BBWC 2 ports Ext PCIe x8 FIO SAS Controller NOTE NOTE NOTE NOTE HP z6000 BBWC HDWR KIT is required when adding BBWC 582653 B21 491193 B21 HP Insight Software HP Insight Software...

Страница 17: ...ad Core Processors Quad Core Processors HP SL160z G6 Intel Xeon E5640 2 66GHz 4 core 12MB 80W Processor Kit 591906 B21 HP SL160z G6 Intel Xeon E5630 2 53GHz 4 core 12MB 80W Processor Kit 591902 B21 HP SL160z G6 Intel Xeon E5620 2 40GHz 4 core 12MB 80W Processor Kit 591904 B21 HP SL160z G6 Intel Xeon L5640 2 26GHz 6 core 12MB 60W Processor Kit 591912 B21 HP SL160z G6 Intel Xeon L5630 2 13GHz 4 core...

Страница 18: ...00 DDR3 1333 Registered CAS 9 Memory Kit 500662 B21 HP 8GB 1x8GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 Low Power Memory Kit NOTE NOTE NOTE NOTE Low Voltage DIMMs can only be used with Intel Xeon processor 5600 series processors 604506 B21 HP 16GB 1x16GB Quad Rank x4 PC3 8500 DDR3 1066 Registered CAS 7 Memory Kit 500666 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CA...

Страница 19: ...r HP 300GB 6G SAS 10K rpm SFF 2 5 inch Quick release Dual Port Enterprise 3yr Warranty Hard Drive 574879 B21 SAS Hot Plug LFF 3 5 inch Midline MDL Drives with quick release QR carrier SAS Hot Plug LFF 3 5 inch Midline MDL Drives with quick release QR carrier SAS Hot Plug LFF 3 5 inch Midline MDL Drives with quick release QR carrier SAS Hot Plug LFF 3 5 inch Midline MDL Drives with quick release QR...

Страница 20: ...ts must be purchased separately HP NC522SFP Dual Port 10GbE Gigabit Server Adapter 468332 B21 HP NC523SFP 10Gb 2 port Server Adapter 593717 B21 HP NC550SFP Dual Port 10GbE Server Adapter 581201 B21 HP NC552SFP 10Gb 2 port Ethernet Server Adapter 614203 B21 NOTE NOTE NOTE NOTE Please see the QuickSpecs for Technical Specifications and additional information www hp com go ProLiantNICs HP 10 GbE PCI ...

Страница 21: ...Hot Plug Power Supply Kit 593188 B21 HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172 B21 HP 750W Common Slot Platinum Hot Plug Power Supply Kit 593831 B21 HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327 B21 HP 1200W Common Slot Platinum Hot Plug Power Supply Kit 578322 B21 NOTE NOTE NOTE NOTE Option Kits contain optional power supply an IEC power cable and PDU IEC cables Qui...

Страница 22: ...E NOTE This part number can be used to purchase one certificate for multiple licenses with a single activation key Each license is for one node server Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment The license entitlement certificate must be redeemed online in order to obtain a license key QL803A HP Cluster Management Utility Li...

Страница 23: ...ontroller Smart Array P212 Controller Smart Array P212 Controller Smart Array P212 Controller NOTE NOTE NOTE NOTE HP P212 SAS 4HDD Cable Kit is required when adding SAS hard drives using the P212 controller 574001 B21 HP Smart Array P212 ZM 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462828 B21 HP Smart Array P212 256 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462834 B21 Smart Array P410 Co...

Страница 24: ...1y 24x7 Supp Physical 1 Svr LTU TC421A NOTE NOTE NOTE NOTE Please see the following QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13203_na 13203_na html Smart Array P212 Controller http h18000 www1 hp com products quickspecs 13201_na 13201_na html Smart Array P410 Controller http h18000 www1 hp com products quickspecs 13202_na 13202_...

Страница 25: ...CSI Tape Library connect AH627A Converged Network Adapter Converged Network Adapter Converged Network Adapter Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter BK835A HP CN1000E Dual Port Converged Network Adapter AW520A HP Modular Smart Array HP Modular Smart Array HP Modular Smart Array HP Modular Smart Array Disk Enclosures Disk Enclosures Disk Enclosures Disk Enclosures ...

Страница 26: ...ck 10000 G2 Series Carbon Graphite Metallic HP 10642 G2 Pallet Universal Rack AF001A HP 10642 G2 Shock Universal Rack AF002A HP 10642 G2 1200mm deep Shock Rack AF092A HP 10647 G2 1200mm deep Shock Rack AF094A NOTE NOTE NOTE NOTE It is mandatory to use a shock pallet when shipping racks with equipment installed NOTE NOTE NOTE NOTE HP ProLiant SL160z G6 models have two different rail kits to choose ...

Страница 27: ...Care Pack Services HP Care Pack Services HP Care Pack Services Hardware Services 4 Hour On site Service Hardware Services 4 Hour On site Service Hardware Services 4 Hour On site Service Hardware Services 4 Hour On site Service HP 3 year 4 hour 24x7 ProLiant DL14x and DL16x Hardware Support U9510E Hardware Services Next Business Day On Site Service Hardware Services Next Business Day On Site Servic...

Страница 28: ...cessor is not installed If only one processor is installed in a 2CPU system only half of the DIMM slots are available To maximize performance balance the total memory capacity between all installed processors It is not required but it is recommended to load the channels similarly if possible If any Quad rank DIMMs are installed all channels are limited to only 2 DIMMs per channel You can only inst...

Страница 29: ... 800 N A N A N A N A N A Supported at 1333 via setting in ROM based setup utility RBSU NOTES NOTES NOTES NOTES PC3 10600 DIMMs have a maximum speed of 1333MHz PC3 8500 DIMMs have a maximum speed of 1066MHz Mixing DIMM speeds is allowed but the system processor speed rules always override the DIMM capabilities If you do mix DIMM speeds the memory bus will default to the minimum clock rate of all DI...

Страница 30: ...er slot population order Chnl 1 1 G empty 1 G empty Chnl 1 2 D empty 2 D empty 3 A 2GB DIMM 3 A empty Chnl 2 4 H empty 4 H empty Chnl 2 5 E empty 5 E empty 6 B 2GB DIMM 6 B empty Chnl 3 7 I empty 7 I empty Chnl 3 8 F empty 8 F empty 9 C 2GB DIMM 9 C empty Standard memory plus optional memory 1 CPU model Standard memory plus optional memory 1 CPU model Standard memory plus optional memory 1 CPU mod...

Страница 31: ...IMM maximum configuration 96GB consisting of six 6 16GB dual rank PC3 8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot population order slot population order Chnl 1 1 G 16GB DIMM 1 G empty Chnl 1 2 D 16GB DIMM 2 D empty 3 A empty 3 A empty Chnl 2 4 H 16GB DIMM 4 H empty Chnl 2 5 E 16GB DIMM 5 E empty 6 B empty 6 B empty Chnl 3 7 I 16GB DIMM 7 I empty Chnl 3 8 F 16GB DIMM 8 F empty 9 C empt...

Страница 32: ...configuration 192GB consisting of twelve 12 16GB PC3 8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot population order slot population order Chnl 1 1 G 16GB DIMM 1 G 16GB DIMM Chnl 1 2 D 16GB DIMM 2 D 16GB DIMM 3 A empty 3 A empty Chnl 2 4 H 16GB DIMM 4 H 16GB DIMM Chnl 2 5 E 16GB DIMM 5 E 16GB DIMM 6 B empty 6 B empty Chnl 3 7 I 16GB DIMM 7 I 16GB DIMM Chnl 3 8 F 16GB DIMM 8 F 16GB DIMM 9...

Страница 33: ...ry options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder Following are memory options available from HP Following are memory options available from HP Following are memory options available from HP Following are memory options available from HP HP Memory HP Memory HP Memory HP Memory Registered DIMMs RDIM...

Страница 34: ...ered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMMs Unbuffered with ECC DIMMs UDIMMs NOTE NOTE NOTE NOTE Maximum 12 DIMMs supported per node HP 1GB 1x1GB Single Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500668 B21 HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500670 B21 HP 4GB 1x4GB Dual Rank x8 PC3 10600 DDR3 1333 ...

Страница 35: ...Kit is required when adding SAS hard drives using the P410 controller SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives with quick release QR carrier SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives with quick release QR carrier SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives with quick release QR carrier SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives with quick release QR carrier Quantity Quantity ...

Страница 36: ...SATA 7 2K Up to 2 1 2 HP Embedded SATA RAID Controller NOTE NOTE NOTE NOTE Transfer rate 3 Gb s SATA SATA Hot Plug SFF 2 5 inch Midline MDL Drives with quick release QR carrier SATA Hot Plug SFF 2 5 inch Midline MDL Drives with quick release QR carrier SATA Hot Plug SFF 2 5 inch Midline MDL Drives with quick release QR carrier SATA Hot Plug SFF 2 5 inch Midline MDL Drives with quick release QR car...

Страница 37: ...n Slot Platinum Hot Plug Power Supply Kit HP 750W Common Slot Platinum Hot Plug Power Supply Kit HP 750W Common Slot Platinum Hot Plug Power Supply Kit HP 750W Common Slot Platinum Hot Plug Power Supply Kit Part Number 593831 B21 Input Voltage Range V rms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 100 100 100 120 120 120 120 200 200 200 200 208 208 208 208 220 220 2...

Страница 38: ...er HP 460W Common Slot Gold Hot Plug Power Supply Kit Supply Kit Supply Kit Supply Kit 503296 B21 Input Voltage Range Input Voltage Range Input Voltage Range Input Voltage Range Vrms 100 to 240 Frequency Range Frequency Range Frequency Range Frequency Range Nominal Hz 50 60 Nominal Input Voltage Nominal Input Voltage Nominal Input Voltage Nominal Input Voltage Vrms 100 100 100 100 120 120 120 120 ...

Страница 39: ...Silver Hot Plug Power Supply Kit Supply Kit Supply Kit Supply Kit 500172 B21 Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range Vrms 100 to 240 Frequency Range Frequency Range Frequency Range Frequency Range Nominal Hz 50 60 Nominal Input Voltage Nominal Input Voltage Nominal Input Voltage Nominal Input Voltage Vrms 100 1...

Страница 40: ...AC Maximum Peak Power See Power Specifications Tables 500Watts at 100 VAC 500 Watts at 200 VAC System Inlet Temperature System Inlet Temperature System Inlet Temperature System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum...

Страница 41: ...d Dual NC362i Integrated Dual NC362i Integrated Dual NC362i Integrated Dual Port Gigabit Server Port Gigabit Server Port Gigabit Server Port Gigabit Server Adapter Adapter Adapter Adapter Network Interface Network Interface Network Interface Network Interface Integrated 10 100 1000BASE T Transceiver Combines a triple speed IEEE 802 3TM Compliant Media Access Controller MAC with a triple speed Ethe...

Страница 42: ...ackard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2012 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Intel ...

Отзывы: