System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
3.46 x 17.64 x 28.1 in (8.79 x 44.80 x 71.37 cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
53.7 lb (24.35 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC
180 to 264 VAC
Rated Input Current
5. 8 Amps (at 100 VAC) to 2.9 Amps (at 200
VAC)
Rated Input Frequency
47 to 63 Hz
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Rated Input Power
570W (at 100 VAC)
565W (at 200 VAC)
Maximum
-500W 1940 BTU / hr (at 100 VAC), 1920
BTU/hr (at 200 VAC)
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 500 Watts (at 100 VAC),
500 Watts (at 200 VAC)
Maximum Peak Power
(See Power Specifications
Tables)
500Watts (at 100 VAC),
500 Watts (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
QuickSpecs
HP ProLiant SL160z Generation 6 (G6)
HP ProLiant SL160z Generation 6 (G6)
HP ProLiant SL160z Generation 6 (G6)
HP ProLiant SL160z Generation 6 (G6)
Technical Specifications
DA - 13385 North America — Version 18 — February 13, 2012
Page 40