Interior View (Rack Model)
1.

System fans: Three (3) fans are standard Optional Five (5) systems fans are shown.

2.

Twenty four DIMM slots: DDR4 Registered (RDIMM) or Load Reduced Registered (LRDIMM) memory

3.

Nine (9) PCIe expansion slots (8 PCIe Gen3 and 1 PCIe Gen2)

4.

Two (2) processors and heatsinks (Second Processor is Optional)

5.

Optional HP Flexible Smart Array or Smart HBA (not shown here)

6.

Optional HP Smart Storage Battery is under the system fans

 

 

 

QuickSpecs

HP ProLiant ML350 Generation9 (Gen9)

Overview

DA - 15035   Worldwide QuickSpecs — Version 2 — 9.23.2014

Page  3

Содержание ProLiant ML350 Generation9

Страница 1: ...anel shown on Rack 3 Slim Height Drive Bay for Optional Slim Height SATA DVD ROM or DVD RW Optical Drive shown on Tower 4 Media Drive Cage Bays Rack supports two half height or one full height device Tower supports one half height device 5 Systems Insight Display Bay for Optional SID Rack models only 6 Two 2 USB 2 0 connectors 7 Unit ID LED button 8 Health LED 9 NIC Activity LED 10 Power On Standb...

Страница 2: ... shown 10 Power supply Power LED 11 Power supply Power connection 12 HP Flexible Slot 1 Power Supply Standard Entry Model 500w Power Supply shown 13 PCI Slots Slots 1 4 Slot 1 and 3 can support Optional GPU 14 Unit ID LED 15 USB 3 0 Connectors 2 top USB 2 0 Connectors 2 bottom 16 Embedded 4 x 1GbE Network Adapter 17 Dedicated iLO Connector 18 Serial Connector 19 Video Connector 20 PCI Slots Slots ...

Страница 3: ...ered LRDIMM memory 3 Nine 9 PCIe expansion slots 8 PCIe Gen3 and 1 PCIe Gen2 4 Two 2 processors and heatsinks Second Processor is Optional 5 Optional HP Flexible Smart Array or Smart HBA not shown here 6 Optional HP Smart Storage Battery is under the system fans QuickSpecs HP ProLiant ML350 Generation9 Gen9 Overview DA 15035 Worldwide QuickSpecs Version 2 9 23 2014 Page 3 ...

Страница 4: ... 65W 9 6GT s 2133 E5 2643v3 3 4GHz 6 20MB 135W 9 6GT s 2133 E5 2640v3 2 6GHz 8 20MB 90W 8 0GT s 1866 E5 2630v3 2 4Ghz 8 20MB 85W 8 0GT s 1866 E5 2630Lv3 1 8GHz 8 20MB 55W 8 0GT s 1866 E5 2620v3 2 4GHz 6 15MB 85W 8 0GT s 1866 E5 2609v3 1 9GHz 6 15MB 85W 6 4GT s 1600 E5 2603v3 1 6GHz 6 15MB 85W 6 4GT s 1600 NOTE E5 2623 v3 will be available in Early 2015 Chipset Intel C610 Series Chipset Intel E5 26...

Страница 5: ...ment number NOTE Nine total expansion slots Three PCIe 3 0 x16 x16 speed One PCIe 3 0 x16 x8 speed Four PCIe 3 0 x8 x4 speed One PCIe 2 0 x8 x4 speed Storage Controller One of the following depending on Model Entry Models HP Dynamic Smart Array B140i Base Models HP Flexible Smart Array P440ar 2GB Performance Models HP Flexible Smart Array P440ar 2GB Internal Storage Devices One of the following de...

Страница 6: ...ly option kit If a different power cord is required please check the ProLiant Power Cables web page To review the power requirements for your selected system please use the HP Power Advisor Tool located at www hp com go hppoweradvisor Power specifications and technical content for all HP Server power supplies can be found at www hp com go proliant powersupply NOTE Mixing of power supplies in the s...

Страница 7: ... available for higher Memory capacity Up to 48 SFF Hard Drive Bays Or 24 LFF Hard Drive Bays 8 PCIe 3 0 and 1 PCIe 2 0 I O slots for additional communications and storage expansion Redundant Power Supply and Redundant Fans Optional optical drive up to 1 Optional System Insight Display NOTE Rack model only Industry Standard Compliance ACPI 2 0b Compliant PCIe 3 0 Compliant PXE Support WOL Support N...

Страница 8: ...properly to support UEFI NOTE HP UEFI FIO Setting 758959 B22 can be selected to configure the system in Legacy mode in the factory Form Factor Tower or Rack 5U Embedded Management HP Integrated Lights Out HP iLO Monitor your servers for ongoing management service alerting reporting and remote management with iLO Learn more at www hp com go ilo UEFI Configure and boot your servers securely with ind...

Страница 9: ...ncludes HP SUM can be downloaded from www hp com go spp download More information can be found http www hp com go SmartUpdate www hp com go spp and http www hp com go hpsum Security Power on password Setup password Serial interface control Power switch security Administrator s password TPM 1 2 UEFI Warranty This product is covered by a global limited warranty and supported by HP Services and a wor...

Страница 10: ...nsight Control software and transition to HP OneView with a free upgrade when available Customers also have the option to purchase HP Insight Control HP Insight Cluster Management Utility CMU HP Insight Cluster Management Utility is a hyperscale optimized management framework that includes software for the provisioning control performance management and monitoring of groups of nodes and infrastruc...

Страница 11: ...rol foundation you need to efficiently manage and visualize your physical and virtual environments Data Replication Software HP offers array based and host based replication software for use in disaster recovery testing application development and reporting Storage Device Management Software Maximize your investment in HP storage and networking with software that enables hardware specific configur...

Страница 12: ...mmendation HP Proactive Care 24x7 coverage three year Care Pack Service This service helps prevent problems and stabilize IT by utilizing secure real time predictive analytics and proactive consultations when your products are connected to HP Includes four hour response for hardware and collaborative call management for software with a two hour callback http h20195 www2 hp com v2 GetPDF aspx 4AA3 ...

Страница 13: ... supported lifetime and or the maximum usage limitations as set forth in the manufacturer s operating manual product quick specs or the technical product data sheet will not be provided repaired or replaced as part of these services The defective media retention service feature option applies only to Disk or eligible SSD Flash Drives replaced by HP due to malfunction QuickSpecs HP ProLiant ML350 G...

Страница 14: ...tallations Please refer to your installation instructions for proper tools and number of people to use for any installation Entry Models Base Models SKU Number 765819 xx1 765820 xx1 Model Name HP ProLiant ML350 Gen9 E5 2609v3 8GB R B140i 8LFF 500W PS Entry Server HP ProLiant ML350 Gen9 E5 2620v3 16GB R P440ar 8SFF 500W PS Base Server Processor Intel Xeon E5 2609v3 Intel Xeon E5 2620v3 Number of Pr...

Страница 15: ...M Optical Drive Optical Drive Optional Slim Optical Bay SATA DVD RW ROM Optical Drive PCI Express Slots 9 PCIe slots Power Supply 2 HP 800W Flex Slot Platinum Power Supply Fans 8 hot plug fans redundant Management iLO Management standard Intelligent Provisioning standard iLO Advanced optional Insight Control optional Energy Star Meets Energy Star requirements Accessories Rack Kit included Form Fac...

Страница 16: ...ect one or two processors from Core options Processor section below If one processor is desired select one xxxxxx L21 If two processors are desired select one xxxxxx L21 and one xxxxxx B21 Up to 2 processors supported Mixing different processor models is not supported DDR4 speed is the maximum memory speed of the processor Actual memory speed may depend on the quantity and type of DIMMs installed ...

Страница 17: ...s provide status and activity indicators as well as caution indicators for Do Not Remove HP Graphics Options Select one or more graphics adapter from Additional options section below Please see the HP Power Advisor for estimated power consumption of your individual system configuration prior to installing GPUs The HP Power Advisor is located at www hp com go hppoweradvisor This section may contain...

Страница 18: ...m of two people are required for all Rack Server installations Please refer to your installation instructions for proper tools and number of people to use for any installation QuickSpecs HP ProLiant ML350 Generation9 Gen9 Configuration Information Factory Integrated Models DA 15035 Worldwide QuickSpecs Version 2 9 23 2014 Page 18 ...

Страница 19: ...model to a rack model 726567 B21 HP ML350 Gen9 System Insight Display Kit NOTE For rack model only 726563 B21 HP Processors Entry Processors E5 2600v3 series Processors HP ML350 Gen9 Intel Xeon E5 2609v3 1 9GHz 6 core 15MB 85W Processor Kit 726661 B21 HP ML350 Gen9 Intel Xeon E5 2609v3 1 9GHz 6 core 15MB 85W FIO Processor Kit 726661 L21 HP ML350 Gen9 Intel Xeon E5 2603v3 1 6GHz 6 core 15MB 85W Pro...

Страница 20: ... ML350 Gen9 Intel Xeon E5 2695v3 2 3GHz 14 core 35MB 120W FIO Processor Kit 726677 L21 HP ML350 Gen9 Intel Xeon E5 2667v3 3 2GHz 8 core 20MB 135W Processor Kit 726680 B21 HP ML350 Gen9 Intel Xeon E5 2667v3 3 2GHz 8 core 20MB 135W FIO Processor Kit 726680 L21 HP ML350 Gen9 Intel Xeon E5 2643v3 3 4GHz 6 core 20MB 135W Processor Kit 726683 B21 HP ML350 Gen9 Intel Xeon E5 2643v3 3 4GHz 6 core 20MB 135...

Страница 21: ... 765424 B21 SAS Hot Plug LFF 3 5 inch Midline MDL Drives HP 6TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 761477 B21 HP 4TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 695510 B21 HP 3TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 652766 B21 HP 2TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 652757 B21 HP 1TB 6G SAS 7...

Страница 22: ...3yr Wty Solid State Drive 691866 B21 HP 200GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691864 B21 HP 100GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691862 B21 6G SATA Hot Plug SFF 2 5 inch Enterprise Value Solid State Drives HP 800GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Value 3yr Wty Sol...

Страница 23: ...Drive 718171 B21 HP 80GB 6G SATA Value Endurance LFF 3 5 in SC Enterprise Boot 3yr Wty Solid State Drive 734362 B21 Hard Drive Blank Kits HP Large Form Factor Hard Drive Blank Kit 666986 B21 HP Small Form Factor Hard Drive Blank Kit 666987 B21 Hard Drive Kits HP ML350 Gen9 SFF Media Cage Kit 726545 B21 HP ML350 Gen9 8LFF Hot Plug Drive Cage Kit 726547 B21 HP ML350 Gen9 LFF Media Cage Kit 726561 B2...

Страница 24: ...n be selected Each requires one Graphic Card Support Kit 726565 B21 NOTE If this SKU is selected then minimum quantity 2 of 800W Power Supply Kit 725870 B21 must be selected 730874 B21 HP NVIDIA Quadro K5200 GPU Graphics Accelerator NOTE Min max rule does not apply to this option A maximum of four of these cards can be selected Each requires one Graphic Card Support Kit 726565 B21 J0G91A HP NVIDIA...

Страница 25: ...uding 1yr 24x7 Support ProLiant ML DL BL bundle FIO Electronic License C6N36ABE HP iLO Advanced including 1yr 24x7 Technical Support and Updates Electronic License TA850AAE HP Security HP Trusted Platform Module Option 488069 B21 HP Security Bezel Kit NOTE Rack model only 660584 B21 NOTE The TPM Trusted Platform Module is a microcontroller chip that can securely store artifacts used to authenticat...

Страница 26: ...mplete range of tape drives autoloaders libraries and media see http www hp com go tape For hardware and software compatibility of HP tape backup products see http www hp com storage SPOCK and http www hp com go ebs Tape Drives HP StoreEver LTO 6 Ultrium 6650 SAS Internal Tape Drive EH963A HP StoreEver LTO 6 Ultrium 6650 SAS External Tape Drive EH964A HP StoreEver LTO 6 Ultrium 6250 Internal Tape ...

Страница 27: ...1100E 16Gb Dual Port Fibre Channel Host Bus Adapter C8R39A QLogic Fibre Channel HBAs HP 81Q 8Gb 1 port PCIe Fibre Channel Host Bus Adapter AK344A HP 82Q 8Gb 2 port PCIe Fibre Channel Host Bus Adapter AJ764A HP StoreFabric SN1000Q 16GB 1 port PCIe Fibre Channel Host Bus Adapter QW971A HP StoreFabric SN1000Q 16GB 2 port PCIe Fibre Channel Host Bus Adapter QW972A Converged Network Adapter HP StoreFab...

Страница 28: ...t Series Rack BW912A HP 647 1200mm Pallet Intelligent Series Rack BW913A HP 647 1200mm Shock Intelligent Series Rack BW914A HP 642 1075mm Pallet Intelligent Series Rack BW903A HP 642 1075mm Shock Intelligent Series Rack BW904A HP 642 1200mm Pallet Intelligent Series Rack BW907A HP 642 1200mm Shock Intelligent Series Rack BW908A HP 636 1075mm Pallet Intelligent Series Rack BW895A HP 636 1075mm Shoc...

Страница 29: ...P Monitored PDU D9N59A HP 22kVA 400 Volt IEC309 32A 3 Phase Input 30xC13 3xC19 INTL Monitored PDU D9N56A HP 22kVA 400 Volt IEC309 32A 3 Phase Input 12xC13 12xC19 INTL Monitored PDU D9N60A NOTE Please see the HP Monitored Power Distribution Units QuickSpecs for information on additional options and product specifications HP Intelligent Power Distribution Units iPDU HP 4 9kVA 24A Single Phase NA JP ...

Страница 30: ... 631346 B21 HP USB BFR with PVC Free ES Keyboard Mouse Kit 631348 B21 HP USB BFR with PVC Free DE Keyboard Mouse Kit 631358 B21 HP USB BFR with PVC Free JP Keyboard Mouse Kit 631360 B21 HP USB BFR with PVC Free IT Keyboard Mouse Kit 631362 B21 HP USB BFR with PVC Free CN Keyboard Mouse Kit 631364 B21 HP USB BFR with PVC Free AE Keyboard Mouse Kit 638212 B21 HP USB BFR with PVC Free RU Keyboard Mou...

Страница 31: ...ptible Power System AF468A HP R5KVA 3U IEC309 32A High Voltage INTL Uninterruptible Power System AF461A HP R7KVA 4U IEC 32A High Voltage INTL Uninterruptible Power System AF463A NOTE To learn more please visit the HP Uninterruptible Power Systems UPS web page HP Care Pack Services Proactive Care HP 3 year 24x7 ML350 Gen9 Proactive Care Service U7BG4E HP 3 year Call to Repair ML350 Gen9 Proactive C...

Страница 32: ... across the two processors White DIMM slots denote the first slot to be populated in a channel Place the DIMMs with the highest number of ranks in the white slot when mixing DIMMs of different ranks on the same channel Do not mix RDIMMs or LRDIMMs Quad rank RDIMMs are not supported in HP ProLiant ML350 Gen9 servers Quad rank LRDIMMs are capable of up to three DIMMs per channel RDIMMs operating at ...

Страница 33: ... Per Channel 2133 2 DIMM Per Channel 2133 3 DIMM Per Channel 1600 1600 1600 DIMM slot and configuration diagram DIMM slot and configuration diagrams Population order start with A first B second C third etc When one processor is installed install DIMMs in sequential alphabetic order A B C D E F When two processors are installed install DIMMs in sequential alphabetic order CPU1 A CPU2 A CPU1 B CPU2 ...

Страница 34: ...Standard Memory Maximum Memory Plus Optional Memory Standard Memory Replaced with Optional Memory E5 2609v3 8GB 1x8GB 376GB 23x16GB 1x8GB 768GB 24x32GB E5 2620v3 16GB 1x16GB 384GB 23x16GB 1x16GB 768GB 24x32GB E5 2630v3 E5 2650v3 32GB 2x16GB 384GB 22x16GB 2x16GB 768GB 24x32GB DDR4 memory options part number decoder NOTE Capacity references are rounded to the common Gigabyte values 2GB 2 048MB 4GB 4...

Страница 35: ...F SATA SAS SSD Hot Pluggable Hard Drive Bays 24 LFF hot plug drive model A Optional Slim DVD ROM DVD RW 1 8 8 x LFF SATA SAS SSD Hot Pluggable Hard Drive Bays QuickSpecs HP ProLiant ML350 Generation9 Gen9 Storage DA 15035 Worldwide QuickSpecs Version 2 9 23 2014 Page 35 ...

Страница 36: ...ut for China only For 500W Power Supply 500W at 100 to 127 VAC 500W at 200 to 240 VAC 500W at 240 VAC input for China only System Inlet Temperature Standard Operating Support 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 20 C hr 36 ...

Страница 37: ...9 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle LWAd 3 6 Bels 1P LFF Entry 3 5 Bels 1P SFF Base 3 6 Bels 2P SFF E star Rack 3 4 Bels 2P SFF E star Tower LpAm 21 dBA 1P LFF Entry 21 dBA 1P SFF Base 20 dBA 2P SFF E star Rack 19 dBA 2P SFF E star Tower Operating LWAd 3 7 Bels 1P LFF Entry 3 6 Bels 1P SFF Base 4 5 Bels 2P SFF E star Rack 4 5 Bels 2P SFF E star Rack LpAm 21 dBA 1P LFF ...

Страница 38: ...trator Supported HP Ethernet 1Gb 4 port 331i Adapter Network Interface 10Base T 100Base TX 1000Base TX Compatibility IEEE 802 3 10Base T IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX Ports Data Transfer Method PCI Express two lanes x2 Controller BCM5719 10Base T Half Duplex 10 Mb s per port 40 Mb s combined 10Base T Full Duplex 20 Mb s per port 80 Mb s combined Network Transfer Rate 100Base TX Ha...

Страница 39: ...cled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as ...

Страница 40: ...roducts and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intel and Xeon are registered trademarks of Intel Corporation in the U S and other countries Microsoft Windows and Windows Server are U S registered trademarks of the Microsoft group of companies For hard drives 1GB 1 ...