Specifications 90
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Nonoperating
-30
°
C to 60
°
C (-22
°
F to 140
°
F)
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Tower model
Rack model
Height
36.82 cm (14.50 in)
17.50 cm (6.89 in)
Depth
47.52 cm (18.71 in)
47.52 cm (18.71 in)
Width
17.50 cm (6.89 in)
36.82 cm (14.50 in)
Weight, minimum for SFF drive cage
11.00 kg (24.22 lb)
11.00 kg (24.22 lb)
Weight, maximum for SFF drive cage
17.00 kg (37.44 lb)
17.00 kg (37.44 lb)
Weight, minimum for LFF drive cage
11.90 kg (26.21 lb)
11.90 kg (26.21 lb)
Weight, maximum for LFF drive cage
19.00 kg (41.85 lb)
19.00 kg (41.85 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP 350 W 4U Factory Integrated Power Supply
•
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
CAUTION:
Check the system and power supply input ratings before powering up the server.
Содержание ProLiant ML310e
Страница 14: ...Component identification 14 Drive numbering Four bay LFF drive model Eight bay SFF drive model ...
Страница 23: ...Operations 23 4 Lock the tower bezel 5 Power up the server on page 18 ...
Страница 43: ...Hardware options installation 43 5 Remove the media bay blank 6 Remove the EMI shield ...
Страница 98: ...Support and other resources 98 ...
Страница 99: ...Support and other resources 99 ...