Hardware options installation 40
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Unlock the tower bezel (on page
19
).
4.
Remove the access panel (on page
20
).
5.
Remove the air baffle (on page
21
).
6.
If necessary, disconnect the Mini-SAS cable from the system board.
7.
Install the storage controller.
8.
Connect all necessary internal and external cabling to the option. For more information on these
cabling requirements, see the documentation that ships with the option. For internal cable routing
information in different drive configurations, see "Storage cabling (on page
61
)."
9.
Install the air baffle (on page
22
).
10.
Install the access panel (on page
21
).
11.
Install the drives ("
Drive options
" on page
30
).
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis unless
all bays are populated with a component or a blank.
12.
Lock the tower bezel.
13.
Connect each power cord to the server.
14.
Connect each power cord to the power source.
15.
Power up the server (on page
18
).
For more information about the controller and its features, see the
HP Smart Array Controllers for HP ProLiant
Servers User Guide
on the HP website (
http://www.hp.com/support/SAC_UG_ProLiantServers_en
). To
configure arrays, see the
Configuring Arrays on HP Smart Array Controllers Reference Guide
on the HP
website (
http://www.hp.com/support/CASAC_RG_en
).
Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs
on the HP website (
http://www.hp.com/support
).
Installing the FBWC module and capacitor pack
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
To install the component:
1.
Power down the server (on page
18
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Unlock the tower bezel (on page
19
).
4.
Remove the access panel (on page
20
).
5.
Remove the air baffle (on page
21
).
Содержание ProLiant ML310e
Страница 14: ...Component identification 14 Drive numbering Four bay LFF drive model Eight bay SFF drive model ...
Страница 23: ...Operations 23 4 Lock the tower bezel 5 Power up the server on page 18 ...
Страница 43: ...Hardware options installation 43 5 Remove the media bay blank 6 Remove the EMI shield ...
Страница 98: ...Support and other resources 98 ...