Battery replacement 100
Battery replacement
If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server (on page
25
).
2.
Extend the server from the rack (on page
25
).
3.
Remove the access panel (on page
26
).
4.
Locate the battery ("
SPI board components
" on page
15
).
5.
Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
Содержание ProLiant DL585 G7
Страница 18: ...Component identification 18 Secondary processor memory board Device numbers ...
Страница 23: ...Component identification 23 Fan locations Power supply backplane components ...
Страница 48: ...Hardware options installation 48 4 Remove the tray 5 Remove the DIMM baffle 6 Install the DIMMs ...
Страница 71: ...Cabling 71 Cabling DVD ROM drive cabling ...
Страница 92: ...Troubleshooting 92 ...
Страница 108: ...Regulatory compliance notices 108 Taiwan notices ...
Страница 117: ...Support and other resources 117 ...
Страница 118: ...Support and other resources 118 ...