Hardware options installation 64
Hard drive cage option
Installation of a SAS expander card or an additional SAS controller option is required to support the hard
drive cage option.
1.
Power down the server (on page
24
).
2.
Extend the server from the rack (on page
24
).
3.
Remove the access panel (on page
25
).
4.
Disconnect and remove the optical drive cables ("
Optical drive cabling
" on page
69
), if installed.
5.
Using a T-15 Torx screwdriver, remove the two optical drive retaining screws, and then remove the
optical drive cage.
6.
Remove the two primary hard drive retaining screws, and then slide the primary hard drive cage
forward.
7.
Install the optional hard drive cage.