System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Weight
Weight
Weight
Weight (approximate)
Maximum
(all hard drives, power
supply, and processor
installed)
60 lb (27.22 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
47.18 lb (20.41 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 - 132 VAC,
200 - 240 VAC
Rated Input Current
10A (at 100 VAC)
9A (at 120 VAC)
6.1A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
980W (at 100 VAC)
1035W (at 120 VAC)
1170W (at 240 VAC)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
3350 BTU/hr (at 100 VAC)
3530 BTU/hr (at 120 VAC)
3990 BTU/hr (at 240 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
NOTE:
NOTE:
NOTE:
NOTE: To review typical system power ratings use the HP Power Advisor
which is available online located at url:
www.hp.com/go/proliant-energy-
efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL380 G5
- Follow the instructions of the next screens.
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Rated Steady-State Power 800 W (at 100 VAC)
850 W (at 120 VAC)
1000W (qt 200-240 VAC)
Maximum Peak Power
800 W (at 100 VAC)
850 W (at 120 VAC)
1000W (at 200-240 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
QuickSpecs
HP ProLiant DL380 Generation 5 (G5)
HP ProLiant DL380 Generation 5 (G5)
HP ProLiant DL380 Generation 5 (G5)
HP ProLiant DL380 Generation 5 (G5)
Technical Specifications
DA - 12477 North America — Version 63 — September 23, 2010
Page 38