Removal and Replacement Procedures
29
6. Remove the component from the server.
CAUTION: When replacing the component, be sure the power
converter module is properly seated in the server chassis.
To replace the component, reverse the removal procedure.
Processor Fan Assembly
CAUTION: Do not operate the server for long periods without
the access panel. Operating the server without the access panel results
in improper airflow and improper cooling that can lead to thermal
damage.
1. Extend or remove the server from the rack ("Extending the Server from the
Rack" on page
17
).
2. Remove the access panel ("Removing the Access Panel" on page
18
).
3. Loosen the thumbscrew that secures the processor fan assembly to the server.
4. Push on the sheet metal tab near the thumbscrew to separate the fan tray
connector from the system board connector.