Arrays
See
. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or more logical units (L1) called arrays. When this is
done, the read/write heads of all the constituent physical drives are active simultaneously, dramatically
reducing the overall time required for data transfer.
NOTE:
Depending on the storage server model, array con
fi
guration may not be possible or necessary.
P1
P3
P2
L1
gl0042
Figure 9 Con
fi
guring arrays from physical drives
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of data
stripes over all the hard drives in an array, as shown in
.
S
1
S
2
S3
S
4
B1
B4
B7
B2
B5
B8
B11
B10
B12
B6
B
3
B9
gl0043
Figure 10 RAID 0 (data striping) (S1-S4) of data blocks (B1-B12)
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the data blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array, the extra capacity is
wasted because it cannot be used by the array.
Fault tolerance
Drive failure, although rare, is potentially catastrophic. For example, using simple striping as shown in
, failure of any hard drive leads to failure of all logical drives in the same array, and hence to
data loss.
To protect against data loss from hard drive failure, storage servers should be con
fi
gured with fault
tolerance. HP recommends adhering to RAID 5 con
fi
gurations.
HP ProLiant DL100 G2 Storage Server administration guide
41
Содержание ProLiant DL100 G2 DPSS
Страница 12: ...12 ...
Страница 18: ...18 About this guide ...
Страница 26: ...26 The HP storage server solution ...
Страница 46: ...46 Storage management overview ...
Страница 134: ...134 Troubleshooting servicing and maintenance ...
Страница 152: ...152 Regulatory compliance and safety ...