HP Storage Controller
HP Smart Array P731m Controller
NOTE:
The HP Smart Array P731m Controller is a Type B mezzanine card that can be
installed in BL660c Gen8 mezzanine slots 2 and 3.
NOTE:
The BL660 has three installation locations for the "capacitor pack" that comes
with the FBWC on Smart Array controllers. The first install location is for the embedded
Smart Array P220i Controller. The second install location is for an optional Smart Array
controller Type A or B mezzanine card with FBWC installed in mezzanine slot 3. The
third install location is for an optional Smart Array controller mezzanine card with FBWC
installed in either mezzanine slot 1 (Type A only) or slot 2 (Type A or B).
HP Smart Array P731m/2GB FBWC 6Gb 4-ports Ext Mezzanine SAS Controller
698535-B21
HP Smart Array P721m Controller
NOTE:
The HP Smart Array P721m Controller is a Type B mezzanine card that can be
installed in BL660c Gen8 mezzanine slots 2 and 3.
NOTE:
The BL660 has three installation locations for the "capacitor pack" that comes
with the FBWC on Smart Array controllers. The first install location is for the embedded
Smart Array P220i Controller. The second install location is for an optional Smart Array
controller Type A or B mezzanine card with FBWC installed in mezzanine slot 3. The
third install location is for an optional Smart Array controller mezzanine card with FBWC
installed in either mezzanine slot 1 (Type A only) or slot 2 (Type A or B).
HP Smart Array P721m/2G FBWC 4-ports Ext Mezzanine SAS Controller
650072-B21
HP Smart Array P721m/512 4-ports Ext Mezzanine SAS Controller
655636-B21
NOTE:
For additional information, please see the HP BladeSystem c7000 Enclosure and
InfiniBand QuickSpecs at::
http://h18000.www1.hp.com/products/quickspecs/14626_na/14626_na.html
.
(Smart Array P731m Controller)
http://h18000.www1.hp.com/products/quickspecs/14404_na/14404_na.html
.
(Smart Array P721M Controller)
HP InfiniBand Mezzanines
NOTE:
When an InfiniBand adapter is installed in mezzanine slot 1, only one port is
active (regardless of operating mode). When installed in any other mezzanine slot, both
ports are active.
NOTE:
InfiniBand QDR and FDR speeds are only supported on the HP BladeSystem
c7000 Enclosure. For additional information, please see the HP BladeSystem c7000
Enclosure and InfiniBand QuickSpecs at:
http://h18004.www1.hp.com/products/quickspecs/12586_na/12586_na.html
http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html
HP Infiniband QDR/Ethernet 10Gb 2-port 544M Adapter
NOTE:
The QDR InfiniBand adapter may be installed in any mezzanine slot of the server.
644160-B21
HP Infiniband FDR/Ethernet 10Gb/40Gb 2-port 544M Adapter
NOTE:
The FDR InfiniBand adapter must be installed in mezzanine slot 1 for FDR mode
and may be installed in any mezzanine slot if operated in any other mode.
644161-B22
QuickSpecs
HP ProLiant BL660c Generation 8 (Gen8) Server Blade
Additional Options
DA - 14394 North America — Version 17 — December 16, 2013
Page 32