Hardware options installation 31
CAUTION:
The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
IMPORTANT:
Processor socket 1 must be populated at all times or the server blade does not
function.
To install the component:
1.
Locate and download the latest ROM version from the HP website (
http://www.hp.com/support
).
Follow the instructions on the website to update the system ROM.
2.
Power down the server blade (on page
14
).
3.
Remove the server blade (on page
15
).
4.
Remove the access panel (on page
16
).
5.
Remove the hard drives.
6.
Remove the front panel/hard drive cage assembly (on page
19
).
7.
Remove the heatsink blank.
CAUTION:
Failure to completely open the processor locking lever prevents the processor from
seating during installation, leading to hardware damage.