background image

platforms.
For more information, see: 

http://www.hp.com/go/iLO/scale-out

HP iLO Advanced License
for ProLiant Servers

HP iLO management processors for HP ProLiant Gen8 servers virtualizes
system controls to help simplify server setup, engage health monitoring and
power and thermal control, and promote remote administration. HP iLO
functions out-of-the-box without additional software installation and
functions regardless of the servers' state of operation. The HP iLO can be
accessed from any location via a web browser and works hand-in-hand with
HP Systems Insight Manager, Insight Control, and Matrix Operating
Environment, helping customers unleash the value of the ProLiant platform
and deliver the highest possible quality of IT service to the business.

Advanced functionality, such as graphical remote console, multi-user
collaboration, and video record/playback can be activated with the optional
HP iLO Advanced or HP iLO Advanced for BladeSystem licenses. The Advanced
licensed features offer sophisticated remote administration of servers in
dynamic data center and remote locations and can help significantly reduce
cost associated with IT-related travel and unplanned downtime.

NOTE:

 For more information, visit 

http://www.hp.com/go/ilo

.

HP OneView

The HP OneView architecture combines server, storage, and networking with control of datacenter
environmentals into a single, integrated management platform. Architected to deliver lifecycle
management for the complete Converged Infrastructure, it facilitates collaboration, removes friction,
collapses cycle times, eliminates error-prone work, and accelerates time to value. HP OneView v1.0
combines management of servers and virtual connect with open integration to automate and customize
existing tools and processes. With OneView, you'll work smarter-with greater visibility and control-and
fully capitalize on the benefits of a Converged Infrastructure.

For more information on HP OneView management, see: 

http://www.hp.com/go/oneview

.

High Performance
Clusters

HP Cluster Platforms

HP Cluster Platforms are specifically engineered, factory-integrated large-
scale ProLiant clusters optimized for High Performance Computing, with a
choice of servers, networks and software. Operating system options include
specially priced offerings for Red Hat Enterprise Linux and SUSE Linux
Enterprise Server, as well as Microsoft Windows HPC Server. A Cluster
Platform Configurator simplifies ordering. 

http://www.hp.com/go/clusters

HP HPC Interconnects

High Performance Computing (HPC) interconnect technologies are available
for this server as part of the HP Cluster Platform portfolio. These high-speed
InfiniBand and Gigabit interconnects are fully supported by HP when
integrated within an HP cluster. Flexible, validated solutions can be defined
with the help of configuration tools.

http://www.hp.com/techservers/clusters/ucp/index.html

HP Insight Cluster
Management Utility

HP Insight Cluster Management Utility (CMU) is an HP-licensed and HP-
supported suite of tools that are used for lifecycle management of hyperscale
clusters of Linux ProLiant systems. CMU includes software for the centralized
provisioning, management and monitoring of nodes. CMU makes the
administration of clusters user friendly, efficient, and effective.

http://www.hp.com/go/cmu

QuickSpecs

HP ProLiant BL460c Generation 8 (Gen8) Server Blade

Optional Features

DA - 14208   North America — Version 31 — December 13, 2013

Page  15

Содержание ProLiant BL460c Gen8

Страница 1: ...or 9 Two 2 small form factor SFF hot plug drive bays 4 FlexibleLOM connectors supporting one 1 FlexibleLOM 10 HP c Class Blade SUV Serial USB VGA connector 5 Sixteen 16 DDR3 DIMM memory slots 8 per processor 11 HP Smart Array P220i Controller with 512MB FBWC 6 HP Smart Array P220i Controller connector 12 Access panel What s New QuickSpecs HP ProLiant BL460c Generation 8 Gen8 Server Blade Overview ...

Страница 2: ...upport for600 GB and 300GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Hard Drives Support for HP Oneview Software License QuickSpecs HP ProLiant BL460c Generation 8 Gen8 Server Blade Overview DA 14208 North America Version 31 December 13 2013 Page 2 ...

Страница 3: ...eatures shipped in the Factory Integrated Models please see the Configuration Information Factory Integrated Models section Processor One of the following depending on Model E5 2600 v2 series Processors Intel Xeon E5 2697 v2 2 7GHz 12 core 30MB 8 0GT s QPI 130W DDR3 1866 HT Turbo2 3 3 3 3 3 3 3 4 5 6 7 8 Intel Xeon E5 2695 v2 2 4GHz 12 core 30MB 8 0GT s QPI 115W DDR3 1866 HT Turbo2 4 4 4 4 4 4 4 4...

Страница 4: ... Intel Xeon E5 2609 2 4GHz 4 core 10MB 6 4GT s QPI 80W Intel Xeon E5 2603 1 8GHz 4 core 10MB 6 4GT s QPI 80W NOTE The Intel Xeon E5 2600 Processor Family cannot be configured with the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage 1 35v HP Smart Memory NOTE DIMM slots 4 and 5 are not accessible when either the E5 2690 the E5 2643 the E5 2643 v2 or the E5 2637 v2 or the E5 2667 v2 is us...

Страница 5: ... slots on the BL460c Gen8 must be fully populated with these 24GB DIMMs When HP 24GB 1x24GB Three Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage FIO Memory Kits are used with either the E5 2690 the E5 2643 the E5 2637 v2 the E5 2643 v2 or the E5 2667 v2 all 12 available DIMM slots on the BL460c Gen8 must be fully populated with these 24GB DIMMs Cache Memory One of the following dependi...

Страница 6: ...00MHz at 1 5V 384GB 16 x 24GB up to 1333MHz at 1 35V Maximum UDIMM 128GB 16 x 8GB up to 1600MHz at 1 5v NOTE HP memory from previous generation servers are not qualified or warranted with this server HP SmartMemory is required to realize the memory performance improvements and enhanced functionality listed in this document for Gen8 For additional information please see the HP SmartMemory QuickSpec...

Страница 7: ...bleLOM NOTE FlexibleLOMs are not compatible with prior generation c Class server blades Standard iLO Network Controller One 1 10 100 Mbps port for the HP iLO 4 to Onboard Administrator link The Onboard Administrator with 10 100 1000 Mbps to BladeSystem link is 1Gbps Expansion Slots Two 2 I O expansion mezzanine slots x16 PCIe 3 0 Type A supports Type A mezzanine cards expansion slot 1 NOTE This ex...

Страница 8: ...r further information please refer to HP s RBSU ROM based setup utility user guide www hp com support rbsu Storage Controller All BTO Models One 1 HP Smart Array P220i Controller with 512MB Flash Backed Write Cache FBWC supporting RAID 0 and RAID 1 NOTE Upgradeable firmware with recovery ROM NOTE The HP Smart Array P220i supports two 2 small form factor SFF hot plug drive bays NOTE The server supp...

Страница 9: ...d Hat Enterprise Linux RHEL SUSE Linux Enterprise Server SLES Canonical Ubuntu Oracle Solaris VMware Citrix XenServer NOTE For more information on HP s Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server please visit our Support Matrix at http www hp com go ossupport and our driver download page http www hp co...

Страница 10: ...ed HP Active Health System Always on continuous monitoring for increased stability and shorter downtimes 100 configuration history Health and service alerts and easy export and upload to Service and Support HP Intelligent Provisioning Lets customers provision and configure a single server without any separate media No more SmartStart CDs or Smart Update Firmware DVD are needed To start Intelligent...

Страница 11: ...user through the steps of discovery analyses and update providing comprehensive information on available updates criticality and interdependencies This information is also available in reports By providing the option of multiple local or shared repositories which can be easily updated from hp com HP SUM provides the tools to optimize stability and consistency throughout the company While HP SUM an...

Страница 12: ...educing the likelihood of unplanned downtime Failed DIMM isolation improves the service time thus improving the overall system availability Address parity protection available on RDIMMs and LRDIMMs detects address bit errors to improve service time and overall system availability Mezzanine options and I O Support for one 1 FlexibleLOM providing two 2 i e redundant Ethernet ports Multiple mezzanine...

Страница 13: ...multaneous redundant fabrics for FlexFabric Virtual Connect Ethernet Fibre Channel InfiniBand Pass Thru Ethernet etc Enclosure crosslinks between adjacent enclosures to provide interconnect module to module connections or as Virtual Connect module stacking links Optional enclosure redundant Onboard Administrator system management module Warranty This product is covered by a global limited warranty...

Страница 14: ... optimize your IT infrastructure through a single simple management console For more information see http www hp com go insightcontrol HP Insight Control includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates For more information about this service see http www hp com services insight HP Matr...

Страница 15: ...ime to value HP OneView v1 0 combines management of servers and virtual connect with open integration to automate and customize existing tools and processes With OneView you ll work smarter with greater visibility and control and fully capitalize on the benefits of a Converged Infrastructure For more information on HP OneView management see http www hp com go oneview High Performance Clusters HP C...

Страница 16: ...orage Device Management Software Maximize your investment in HP storage and networking with software that enables hardware specific configuration performance tuning and connectivity management HP StoreVirtual VSA HP StoreVirtual VSA allows you to create fully featured shared storage on a VMware vSphere or Microsoft Hyper V virtualized server This server model starting November 2013 includes a limi...

Страница 17: ...uration and design services as well as individual factory services such as image loading asset tagging and custom packaging HP products supported through Factory Express include a wide array of servers and storage HP Integrity HP ProLiant HP ProLiant Server Blades HP BladeSystem HP 9000 servers as well as the MSAxxxx VA7xxx EVA XP rackable tape libraries and configurable network switches For more ...

Страница 18: ...olved http h20195 www2 hp com v2 GetPDF aspx 4AA3 8855EEE pdf HP Install c Class Server Blade Service This easy to buy easy to use HP Care Pack service helps ensure that your new HP hardware is installed smoothly efficiently and with minimal disruption of your IT and business operations Standard Care 3 Year HP 24x7 4 hour response Proactive Care Service This service gives you combined reactive and...

Страница 19: ...ight Remote Support and HP Support Center are available at no additional cost with a HP warranty HP Care Pack or HP contractual support agreement NOTE HP Support Center Mobile App is subject to local availability Parts and Materials HP will provide HP supported replacement parts and materials necessary to maintain the covered hardware product in operating condition including parts and materials fo...

Страница 20: ...ntroller with 512MB FBWC RAID 0 1 Hard Drive None ship standard Supports up to two 2 HP hot plug SFF SAS SATA SDD drives Internal Storage SAS 2 4TB SATA 2 0TB SAS SSD 1 6TB SATA SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot 1 supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management HP iLO Management Engine standard Optional HP iLO Scale Out or...

Страница 21: ... SATA 2 0TB SAS SSD 1 6TB SATA SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot 1 supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management HP iLO Management Engine standard Optional HP iLO Scale out or HP Insight Control Form Factor Up to eight 8 half height blades supported in the HP BladeSystem c3000 Enclosure Up to sixteen 16 half height blade...

Страница 22: ...d Supports up to two 2 HP hot plug SFF SAS SATA SDD drives Internal Storage SAS 2 0TB SATA 2 0TB SAS SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot 1 supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management HP iLO Management Engine standard Optional HP iLO Scale out or HP Insight Control Form Factor Up to eight 8 half height blades supported in...

Страница 23: ...Storage Controller HP Smart Array P220i Controller with 512MB FBWC RAID 0 1 Hard Drive None ship standard Supports up to two 2 HP hot plug SFF SAS SATA SDD drives Internal Storage SAS 2 4TB SATA 2 0TB SAS SSD 1 6TB SATA SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot 1 supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management HP iLO Management En...

Страница 24: ... HT Turbo2 5 5 6 6 7 7 8 8 Cache Memory 20MB 1x20MB Level 3 cache Memory 64GB 8x 8GB PC3 12800R DDR3 1600 Registered DIMMS at 1 5V NOTE Total of 16 DIMM slots Network Controller HP FlexFabric 10Gb 2 port 554FLB FlexibleLOM Storage Controller HP Smart Array P220i Controller with 512MB FBWC RAID 0 1 Hard Drive None ship standard Supports up to two 2 HP hot plug SFF SAS SATA SDD drives Internal Stora...

Страница 25: ...ts 3 year Labor 3 year on site support HP ProLiant BL460c Gen8 E5 2650L 1P 32GB R P220i SFF Server 666163 B21 Processor s 1 Intel Xeon E5 2650L 1 8GHz 8 core 20MB 8 0GT s QPI 70W DDR3 1600 HT Turbo2 2 2 3 3 4 4 5 5 Cache Memory 20MB Level 3 cache Memory 32GB 4x 8GB PC3L 10600R DDR3 1333 Registered DIMMs at 1 35V NOTE Total of 16 DIMM slots Only eight 8 usable with single processor Network Controll...

Страница 26: ...ar Labor 3 year on site support HP ProLiant BL460c Gen8 E5 2620 1P 16GB R P220i SFF Server 666161 B21 Processor s 1 Intel Xeon E5 2620 2 0GHz 6 core 15MB 7 2GT s QPI 95W DDR3 1333 HT Turbo2 3 3 4 4 5 5 Cache Memory 15MB 1x15MB Level 3 cache Memory 16GB 4x 4GB PC3L 10600R DDR3 1333 Registered DIMMs at 1 35V NOTE Total of 16 DIMM slots Only eight 8 usable with single processor Network Controller HP ...

Страница 27: ...t plug SFF SAS SATA SDD drives Internal Storage SAS 2 4TB SATA 2 0TB SAS SSD 1 6TB SATA SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot 1 supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management HP iLO Management Engine standard Optional HP iLO Scale out or HP Insight Control Form Factor Up to eight 8 half height blades supported in the HP Blade...

Страница 28: ...arts 3 year Labor 3 year on site support HP ProLiant BL460c Gen8 E5 2650 2P Svr S Buy 670656 S01 Processor s 2 Intel Xeon E5 2650 2 0GHz 8 core 20MB 95W 64GB Cache Memory 20MB 1x20MB Level 3 cache Memory 64GB 8x 8GB PC3 12800R DDR3 1600 Registered DIMMs at 1 5V NOTE Total of 16 DIMM slots Network Controller HP FlexFabric 10Gb 2 port 554FLB FlexLOM Storage Controller HP Smart Array P220i Controller...

Страница 29: ...3 year Labor 3 year on site support HP ProLiant BL460c Gen8 E5 2620 2P Svr S Buy 670658 S01 Processor s 2 Intel Xeon E5 2620 2 0GHz 6 core 15MB 95W Cache Memory 15MB 1x15MB Level 3 cache Memory 32GB 4x 8GB PC3L 10600R DDR3 1333 Registered DIMMs at 1 35V NOTE Total of 16 DIMM slots Network Controller HP FlexFabric 10Gb 2 port 554FLB FlexLOM Storage Controller HP Smart Array P220i Controller with 51...

Страница 30: ...Labor 3 year on site support HP ProLiant BL460c Gen8 E5 2640v2 2P Svr S Buy 741447 S01 Processor s 2 Intel Xeon E5 2640 v2 2 0GHz 8 core 20MB 7 2GT s QPI 95W DDR3 1600 HT Turbo2 3 3 3 3 3 3 4 5 Cache Memory 20MB 1x20MB Level 3 cache Memory 48GB 6x 8GB Single Rank x4 PC3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Network Controller HP FlexFabric 10Gb 2 port 534FLB FlexibleLOM Storage Co...

Страница 31: ...rts up to two 2 HP hot plug SFF SAS SATA SDD drives Internal Storage SAS 2 0TB SATA 2 0TB SAS SSD 1 6TB Optical Drive Bay None Expansion Slots 2 standard Slot1supports Type A mezzanine Cards Slot 2 supports Type A and Type B mezzanine cards Management iLO Management Engine Standard Form Factor Up to eight 8 half height blades supported in the HP BladeSystem c3000 Enclosure Up to sixteen 16 half he...

Страница 32: ...e supported 10Gb FlexibleLOMs see Step 2 One 1 HP Smart Array P220i Controller with 512MB FBWC and RAID 0 and 1 support Two 2 HP small form factor hot plug SAS SATA SSD hard drive bays Two 2 x16 PCIe I O expansion slots one Type A one Type A B One 1 integrated USB connector and one 1 MicroSDHC connector One 1 TPM connector HP iLO Management Engine standard NOTE The HP ProLiant BL460c Gen8 10Gb Fle...

Страница 33: ...cessor Kit 718363 L21 E5 2600 series Processors HP BL460c Gen8 Intel Xeon E5 2690 2 9GHz 8 core 20MB 135W FIO Processor Kit 662076 L21 HP BL460c Gen8 Intel Xeon E5 2680 2 7GHz 8 core 20MB 130W FIO Processor Kit 662063 L21 HP BL460c Gen8 Intel Xeon E5 2670 2 6GHz 8 core 20MB 115W FIO Processor Kit 662064 L21 HP BL460c Gen8 Intel Xeon E5 2667 2 9GHz 6 core 15MB 130W FIO Processor Kit 667804 L21 HP B...

Страница 34: ...erver must be identical NOTE All processors support Intel Hyper Threading and Intel Turbo Boost Technologies except the E5 2603 and E5 2609 NOTE The letter L following the model number indicates denotes lower wattage NOTE The processor model as well as the memory configuration determines the maximum speed memory can operate Please see the see the Memory section later in this document NOTE The Inte...

Страница 35: ...C3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Kit 713981 B21 HP 4GB 1x4GB Single Rank x4 PC3 14900R DDR3 1866 Registered CAS 13 Memory Kit 708637 B21 HP 8GB 1x8GB Single Rank x4 PC3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Kit 731765 B21 HP 8GB 1x8GB Single Rank x4 PC3 14900R DDR3 1866 Registered CAS 13 Memory Kit 731761 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 12800R DDR3 16...

Страница 36: ...Kit 669324 B21 HP 8GB 1x8GB Dual Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647909 B21 Load Reduced DIMMs LRDIMMs E5 2600 v2 series Processors HP 32GB 1x32GB Quad Rank x4 PC3 14900L DDR3 1866 Load Reduced CAS 13 Memory Kit 708643 B21 Load Reduced DIMMs LRDIMMs E5 2600 series Processors HP 32GB 1x32GB Quad Rank x4 PC3L 10600L DDR3 1333 Load Reduced CAS 9 Low Voltage Memor...

Страница 37: ... HP OneView for Blade Server incl 3yr 24x7 Supp FIO Bundle 1 Svr E LTU F6Q89AAE HP Storage Controllers HP Smart Array P220i Controller FIO Kit 690164 B21 HP Storage Blades HP D2220sb Configure to order Storage Blade QW918A Step 4 Choose Additional Options for Factory Integration NOTE For additional options please refer to the Core Options and Additional Options section below For additional options...

Страница 38: ...cs 14218_na 14218_na html 674764 B21 HP FlexFabric 10Gb 2 port 554M Adapter NOTE Please see QuickSpecs for technical specifications and additional information at http h18000 www1 hp com products quickspecs 14221_na 14221_na html 647590 B21 1 Gigabit Ethernet Mezzanines HP Ethernet 1Gb 4 port 366M Adapter NOTE Please see QuickSpecs for technical specifications and additional information at http h18...

Страница 39: ...n E5 2680v2 2 8GHz 10 core 25MB 115W Processor Kit 718056 B21 HP BL460c Gen8 Intel Xeon E5 2670v2 2 5GHz 10 core 25MB 115W Processor Kit 718057 B21 HP BL460c Gen8 Intel Xeon E5 2667v2 3 3GHz 8 core 25MB 130W Processor Kit 718366 B21 HP BL460c Gen8 Intel Xeon E5 2660v2 2 2GHz 10 core 25MB 95W Processor Kit 718058 B21 HP BL460c Gen8 Intel Xeon E5 2650v2 2 6GHz 8 core 20MB 95W Processor Kit 718358 B2...

Страница 40: ...e processor model supports Intel Hyper Threading Technology NOTE Turbo indicates the maximum potential frequency increment when using Intel Turbo Boost Technology with 8 7 6 5 4 3 2 or 1 core s active NOTE DDR3 speed is the maximum memory speed of the processor Actual memory speed may depend on the quantity and type of DIMMs installed NOTE Up to 2 processors supported Mixing different processor mo...

Страница 41: ...rver NOTE For additional memory rules and guidelines see the Memory section later in this document NOTE When HP 24GB 1x24GB Three Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage FIO Memory Kits are used with any processors except the E5 2690 the E5 2643 the E5 2637 v2 the E5 2643 v2 or the E5 2667 v2 all 16 DIMM slots on the BL460c Gen8 must be fully populated with these 24GB DIMMs When...

Страница 42: ... DIMMs UDIMMs E5 2600 series Processors HP 2GB 1x2GB Single Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669320 B21 HP 2GB 1x2GB Single Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669322 B21 HP 4GB 1x4GB Dual Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory...

Страница 43: ...ch SC Enterprise 3yr Warranty Hard Drive 652589 B21 HP 600GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652583 B21 HP 450GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652572 B21 HP 300GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652564 B21 HP 300GB 6G SAS 15K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652611 B21 HP 1...

Страница 44: ...nce 3yr Warranty Solid State Drive 653082 B21 HP 200GB 6G SAS SLC SFF 2 5 inch SC Enterprise Performance 3yr Warranty Solid State Drive 653078 B21 6G SATA ME Hot Plug SFF 2 5 inch Enterprise Mainstream Solid State Drives HP 800GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691868 B21 HP 400GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mains...

Страница 45: ...2AAE HP Insight Control Server Deployment including 1yr 24x7 Support Single Server License 452151 B21 NOTE Licenses ship without media The HP Insight Management Media Kit can be ordered separately or can be downloaded at http www hp com go insightupdates NOTE Customer will receive a license entitlement certificate which must be redeemed online or via fax in order to obtain the license activation k...

Страница 46: ...r 24x7 Supp Phys 1 Svr Lic E5Y38A HP OneView w o iLO Adv inc 3yr 24x7 Supp Flex Qty E LTU E5Y39AAE NOTE For additional license kits please see the QuickSpecs at http h18004 www1 hp com products quickspecs 14621_na 14621_na html High Performance Clusters HP Cluster Management Utility HP Insight Cluster Management Utility 1yr 24x7 Flexible License QL803B HP Insight Cluster Management Utility 3yr 24x...

Страница 47: ...er 698535 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information at http h18000 www1 hp com products quickspecs 14404_na 14404_na html Smart Array P721M Controller http h18000 www1 hp com products quickspecs 14626_na 14626_na html Smart Array P731M Controller HP InfiniBand Mezzanines NOTE When an InfiniBand adapter is installed in mezzanine slot 1 only one port ...

Страница 48: ...ery organization end to end case ownership from a Technical Solution Specialists and Technical Account Manager who remotely delivers firmware software revision management proactive scans and incident trend reports Recommended for customers running a virtualized infrastructure and or customers who desire an enhanced call support experience HP 3 year 4 hour 24x7 ProLiant BL4xxc Proactive Care Servic...

Страница 49: ...s of different speeds may be mixed in any order the server will select a common optimal speed The maximum memory speed is a function of the memory type memory configuration and processor model The maximum memory capacity is a function of the memory type and number of installed processors HP memory from previous generation servers is not compatible with the BL460c Gen8 Server Blade To realize the p...

Страница 50: ...2 or the E5 2667 v2 all 16 DIMM slots on the BL460c Gen8 must be fully populated with these 24GB DIMMs When HP 24GB 1x24GB Three Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage FIO Memory Kits are used with either the E5 2690 the E5 2643 the E5 2637 v2 or the E5 2643 v2 or the E5 2667 v2 all 12 available DIMM slots on the BL460c Gen8 must be fully populated with these 24GB DIMMs NOTE Th...

Страница 51: ...650L E5 2637 1600 1333 1066MHz E5 2640 E5 2630 E5 2630L E5 2620 1333 1066MHz E5 2609 E5 2603 1066MHz Memory Speed by E5 2600 v2 Series Processor Model Processor Models Supported Memory Speeds E5 2697 v2 E5 2695 v2 E5 2690 v2 E5 2680 v2 E5 2670 v2 E5 2667 v2 E5 2660 v2 E5 2650 v2 E5 2643 v2 E5 2637 v2 1866 1600MHz E5 2640 v2 E5 2630 v2 E5 2620 v2 E5 2650L v2 E5 2630L v2 1600MHz E5 2609 v2 E5 2603 v...

Страница 52: ...OM Configure to order Blade Server 641016 B21 cannot be configured the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage 1 35v HP Smart Memory NOTE HP memory from previous generation servers are not qualified or warranted with this HP ProLiant BL460c Gen8 Server HP SmartMemory is required to realize the memory performance improvements and enhanced functionality listed in this document for...

Страница 53: ...R DDR3 1600 Registered CAS 11 Memory Kit 647899 B21 HP 8GB 1x8GB Dual Rank x4 PC3 12800R DDR3 1600 Registered CAS 11 Memory Kit 690802 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage Memory Kit 647901 B21 HP 16GB 1x16GB Dual Rank x4 PC3 12800R DDR3 1600 Registered CAS 11 Memory Kit 672631 B21 Unbuffered with ECC DIMMs UDIMMs E5 2600 v2 series Processors HP 4GB 1x...

Страница 54: ...d Reduced CAS 13 Memory Kit 708643 B21 Load Reduced DIMMs LRDIMMs E5 2600 series Processors HP 32GB 1x32GB Quad Rank x4 PC3L 10600L DDR3 1333 Load Reduced CAS 9 Low Voltage Memory Kit 647903 B21 NOTE Depending on the memory configuration and processor model 1600MHz and 1333MHz memory may operate at a lower speed Please see the see the Memory section later in this document and the Online Memory Con...

Страница 55: ...ution must be purchased separately and is available from solution vendor s authorized resellers HP does not resell or factory integrate the solution NOTE This solution is supported by the vendor on servers HP ProLiant BL460c Gen8 Server Blade HP ProLiant WS460c Gen8 Graphics Expansion Blade NOTE Teradici PCoIP and PC over IP are trademarks of Teradici Corporation and may be registered in the Unite...

Страница 56: ...per every 1 000 ft above sea level to a maximum of 3 050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and number of options installed System performance may be reduced if operating with a fan fault or above 30 C 86 F Non operating 30 to 60 C 22 to 140 F Maximum rate of change is 20 C hr 36 F hr Relative Humidity non c...

Страница 57: ...encing 1Gb 10Gb Ethernet capability Network Processor Emulex BE3 Data Transfer Method x8 PCI Express 2 0 Network Transfer Rate Two ports each at 20Gbps full duplex 40Gbps aggregate full duplex theoretical bandwidth NOTE Each port is autosensing 1Gb 10Gb and can interoperate with 1Gb or 10Gb HP BladeSystem c Class interconnect components Both ports will operate at the same speed NOTE Each port on t...

Страница 58: ...by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2013 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Intel the Intel logo Xeon and Xeon Inside are trademarks of Intel Corporation in ...

Отзывы: