Server Blade Configuration and Utilities
Table 5-1: RBSU Default Settings
continued
Menu/Option Default
Setting
Virtual Install Disk
Disabled
Serial Number
Product ID
HW Prefetcher
Enabled
Adjacent Sector Prefetch
Enabled
ProLiant Power Governor
Full Performance
Mode
Utility Language
English
Fan Redundancy
The Fan Redundancy Configuration option determines the behavior of the server if
one or more of the cooling fans fail. This feature requires that the HP System
Management driver be installed.
When the Fan Redundancy option is enabled and the HP System Management driver
is installed, the server will not shut down if only one fan fails. If the system
experiences multiple fan failures, the HP System Management Driver shuts down the
operating system. Additionally, the System ROM will not allow the server to
complete POST if any fan fails.
When the Fan Redundancy option is disabled, the server treats all fans as critical and
shuts down the server if any fan fails.
5-10
HP ProLiant BL20p Generation 3 Server Blade User Guide