background image

61195868L1-13C, August 2005

Printed in the USA

Copyright 2005 Hewlett-Packard Development Company, LP

Quick Start Guide

5990-8864

ProCurve Secure Router dl 1xE1 Module

J8454A

1

X

E1 M

ODULE

 C

OMMANDS

clock source [line* | internal]

Configures the source timing used for the interface. Use the 

no 

form of this command 

to return to the default value.

line*

Recovers clock from the E1 circuit.

internal

Provides clocking using the internal oscillator.

coding [ami | hdb3*]

Configures the line coding for the E1 physical interface. The settings must match the 
line coding supplied on the circuit by the service provider.

ami

Configures the line coding for alternate mark inversion.

hdb3

*

Configures the line coding for high-density bipolar 3.

description <text>

Comment line to provide an identifier for this interface (for example, circuit ID, contact 
information, etc.).

<text>

Shows up to 80 alphanumeric characters.

framing [crc4]

Configures the framing format of the E1 interface. This setting must match the framing 
format provided by the service provider or external device. Use the

 no

 form of this 

command to return to the default value.

crc4

Enables CRC-4 framing.

loop-alarm-detect

Enables detection of loop alarms on the E1 interface. Use the 

no

 form of this command 

to disable loop alarm detection. This setting is enabled by default.

loopback network [line | payload]

Initiates a loopback on the interface toward the network. Use the 

no

 form of this 

command to deactivate the loopback.

line

Initiates a metallic loopback of the physical E1 network 
interface.

payload

Initiates a loopback of the E1 framer (CSU portion) of the E1 
network interface.

loopback remote v54

Initiates an E1 remote loopback test (with a V54 loopback pattern). Use the 

no

 form of 

this command to deactivate the loopback.

remote-alarm [rai* | ais]

Selects the alarm signaling type to be sent when a loss of frame is detected on the E1 
receive signal. Use the 

no

 form of this command to disable all transmitted alarms.

rai*

Sends a remote alarm indication (RAI) in response to a loss 
of frame. Also prevents a received RAI from causing a 
change in interface operational status.

ais

Sends an alarm indication signal (AIS) as an unframed all-
ones signal.

remote-loopback

Configures the interface to respond to loopbacks initiated by a remote unit (or service 
provider). Use the 

no

 form of this command to disable this feature. This setting is 

enabled by default.

sa4tx-bit [0 | 1*]

Selects the Tx value of Sa4 on this E1 interface. Use the 

no

 form of this command to 

return to the default value of 1.

show test-pattern

Displays the results (including error count) from active test patterns. 

shutdown

Disables the interface (both physical and virtual) so that no data will be passed through. 
Use the 

no

 form of this command to turn on the interface and allow it to pass data. By 

default, all interfaces are disabled.

snmp trap link-status

Controls the SNMP variable, 

ifLinkUpDownTrapEnable

 (RFC2863) to enable the 

interface to send SNMP traps when there is an interface status change. Use the 

no

 form 

of this command to disable this trap.

tdm-group

 

<group#> timeslots <1-31> speed [56 | 64*]

Creates a group of contiguous channels on this interface to be used during the bind 
process.

<group#>

Number label (1 to 255) to identify this TDM group.

timeslot <1-31>

Specifies the timeslots used in the TDM group. Enter as a single 
number (representing one of the 31 E1 channel timeslots) or as a 
contiguous group of channels. (For example, 1-10 specifies the 
first ten channels of the E1.)

56 | 64*

(Optional)

 Specifies a channel rate of 56 kbps or 64 kbps.

test-pattern [clear | insert | ones | p511 | qrss | zeros]

Activates the built-in pattern generator and begins sending the specified test pattern. 
Can be used to verify a data path when used in conjunction with an active loopback. Use 
the 

no

 form of this command to cease pattern generation.

clear

Clears the test pattern error count. Display the error count using 
the 

show test-pattern

 command.

insert

Inserts an error into currently active test pattern. Display the 
injected error result using the 

show test-pattern

 command.

ones

Generates a pattern of continuous ones.

p511

Generates repeating pattern of ones and zeros.

qrss

Generates a random pattern.

zeros

Generates a pattern of continuous zeros.

ts16

Enables timeslot 16 multiframe to be checked on the receive signal. Use the 

no

 form of 

this command to disabled timeslot 16.

* Indicates default values.

Note

This command list is an illustration of available commands. 
For complete command descriptions and default values, refer 
to the SROS Command Line Interface Reference Guide 
provided on your ProCurve SROS Documentation CD.