background image

hp

procurve switch

gl/xl redundant power supply

installation guide

www.hp.com/go/hpprocurve

redundant

power

Содержание Procurve GL

Страница 1: ...hp procurve switch gl xl redundant power supply installation guide www hp com go hpprocurve redundant power ...

Страница 2: ......

Страница 3: ...HP Procurve Switch GL XL Redundant Power Supply Installation Guide glxl rps_ed2 book Page i Wednesday May 1 2002 10 43 AM ...

Страница 4: ... IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Hewlett Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett Packard Warranty...

Страница 5: ... 2 Installation Cautions 2 Installation Steps 3 Troubleshooting 6 Customer Support Services 6 Specifications 7 Physical 7 Electrical 7 Environmental 7 Safety 7 Safety Information 8 EMC Regulatory Statements 15 glxl rps_ed2 book Page iii Wednesday May 1 2002 10 43 AM ...

Страница 6: ...glxl rps_ed2 book Page iv Wednesday May 1 2002 10 43 AM ...

Страница 7: ...e power supplies hot swap operation you can add or replace one of the Power Supplies without having to shut down or reboot the switch automatic fault detection if the power supply encounters a problem the Series 4100GL and Series 5300XL Switches can immediately detect the condition and report it via the Power Status and Fault LEDs on the switch Event messages will also be displayed in the switch c...

Страница 8: ...rent protection To determine the possibility of overloading the supply circuits add together the ampere ratings of all devices installed on the same circuit as the switch with this power supply and compare the total with the rating limit for the circuit The maximum ampere ratings are usually printed on the devices near their AC power connectors Do not install the power supply into a switch that is...

Страница 9: ...at AC power is not connected to the power supply being installed before installing the power supply into the switch The switch can be receiving power from the other power supply during the instal lation of the second unit 3 Tighten the four retaining screws that hold the power supply in place until the screws are secure as shown in the next illustration The screws can be tightened with either a fl...

Страница 10: ...unded electrical outlet To provide true redundancy the second power supply should be connected to a different AC power source from the other supply Then if one AC power source fails the switch will continue to run tighten the four screws Connect the power cord to the new power supply glxl rps_ed2 book Page 4 Wednesday May 1 2002 10 43 AM ...

Страница 11: ...Power Status LED for the power supply you have just installed will be blinking simultaneously with the Fault LED until that new power supply is connected to an AC power source Once it is connected to AC power the Power Status LED will be on continuously and not blinking and the Fault LED will stop blinking If the Power Status LED and the switch Fault LED continue blinking after the power supply is...

Страница 12: ...e that the AC power cord is disconnected from the supply before removing and reinstalling the supply If the power source and power cord are OK and this condition persists the switch power supply may be faulty Call your HP authorized LAN dealer or use the electronic support services from HP to get assistance See the Customer Support Warranty booklet supplied with the power supply for more informati...

Страница 13: ...L 1950 Width 20 1 cm 7 9 in Depth 15 0 cm 5 9 in Height 12 8 cm 5 1 in Weight 1 5 kg 3 3 lbs AC voltage 100 127 volts 200 240 volts Maximum current 8 2 A max 3 8 A max Frequency range 50 60 Hz 50 60 Hz Operating Non Operating Temperature 0 C to 55 C 32 F to 131 F 40 C to 70 C 40 F to 158 F Relative humidity non condensing 15 to 95 at 40 C 104 F 15 to 90 at 65 C 149 F Maximum altitude 4 6 Km 15 000...

Страница 14: ...urbances in the electrical utilities power grid Handle exposed metal components of the network with caution Servicing There are no user serviceable parts inside these products Any servicing adjustment maintenance or repair must be performed only by service trained personnel These products do not have a power switch they are powered on when the power cord is plugged in Documentationreferencesymbol ...

Страница 15: ...la foudre ou des perturba tions dans le réseau d alimentation public Manipulez les composants métalliques du réseau avec précautions Aucune pièce contenue à l intérieur de ce produit ne peut être réparée par l utilisateur Tout dépannage réglage entretien ou réparation devra être confié exclusivement à un personnel qualifié Cet appareil ne comporte pas de commutateur principal la mise sous tension ...

Страница 16: ...bestandteile des Netzwerkes Vorsicht walten lassen Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile Wartungs Anpassungs Instandhaltungs oder Reparaturarbeiten dürfen nur von geschultem Bedienungspersonal durchgeführt werden Dieses Gerät hat keinen Netzschalter es wird beim Anschließen des Netzkabels eingeschaltet Symbol für Dokumentationsverweis Wenn das Produkt mit diesem Sy...

Страница 17: ...ricolose tensioni transitorie ad esempio provocate da lampi o disturbi nella griglia d alimen tazione della società elettrica siate cauti nel toccare parti esposte in metallo della rete Nessun componente di questo prodotto può essere riparato dall utente Qualsiasi lavoro di riparazione messa a punto manutenzione o assistenza va effettuato esclusi vamente da personale specializzato Questo apparato ...

Страница 18: ... de vez en cuando a voltajes momentáneos que entrañen peligro rayos o alteraciones en la red de energía eléctrica Manejar con precaución los componentes de metal de la LAN que estén al descubierto Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario Todas las reparaciones ajustes o servicio de mantenimiento debe realizarlos sola mente el técnico Este producto no ti...

Страница 19: ...13 Safety Information Japan Safety Information Japan glxl rps_ed2 book Page 13 Wednesday May 1 2002 10 43 AM ...

Страница 20: ...14 Safety Information China Safety Information China glxl rps_ed2 book Page 14 Wednesday May 1 2002 10 43 AM ...

Страница 21: ... ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense Canada This product complies with Class A Canadian EMC requirements Aus...

Страница 22: ...rmity This product is designed for operation with the HP Procurve Series 4100GL and Series 5300XL Switches Please see the Declaration of Conformity included in the Installation and Getting Started Guide included with the switch glxl rps_ed2 book Page 16 Wednesday May 1 2002 10 43 AM ...

Страница 23: ...glxl rps_ed2 book Page 17 Wednesday May 1 2002 10 43 AM ...

Страница 24: ... Company 2001 2002 All rights reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Produced in U S A Edition 2 May 2002 Manual Part Number J4839 90001 J4839 90001 glxl rps_ed2 book Page 18 Wednesday May 1 2002 10 43 AM ...

Отзывы: