4-5
Planning and Implementation for the 2600-PWR Switches
Planning the PoE Configuration
P
lann
ing and
Implemen
ta
tion for the 2600-
PWR Sw
itc
h
e
s
■
When two switches are connected to the 600 RPS/EPS ports, the PoE
power available to each switch is a maximum of 204 W. If all of your PDs
consume on average less than 7.5 W each (allowing for any line loss) then
all 24 ports will receive redundant power should a switch’s internal PoE
power supply fail.
Redundant power is available as long as the total power required remains
below 204 W.
Source of
Power
Watts
Available
# of Ports Powered and
Average watts/Port
Redundant # of Ports
Powered and Average watts/
Port
Internal PoE
Power Supply
406
24 @ average 15.4 W each None
Internal plus
External PoE
Power Supply
406 + 204
1 - 24
24 @ average 15.4 W each 24 @ 7.5 W each
12 @ 15.4 W each
External PoE
Power Supply
(Failed Internal
PoE Power
Supply)
204
24 @ 7.5 W each
12 @ 15.4 W each
None
Содержание ProCurve 600
Страница 1: ...Power over Ethernet HP ProCurve Power over Ethernet PoE PoE Planning and Implementation Guide ...
Страница 2: ......
Страница 3: ...Power over Ethernet PoE PoE Planning and Implementation Guide ...
Страница 42: ......
Страница 66: ......
Страница 70: ......
Страница 80: ......
Страница 90: ......
Страница 102: ......
Страница 120: ......
Страница 152: ......
Страница 156: ......
Страница 165: ...Index 3 Index system power 5412zl 8212zl 10 5 10 6 T threshold configuing global 2 6 configuring per slot 2 6 ...
Страница 166: ......
Страница 167: ......