![HP ProCurve 1600M Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_installation-manual_155303038.webp)
2-20
Installing the Switch 1600M and 2424M
Hot Swapping the Switch Module
In
stalling the Swit
c
h
1600M
a
nd 2424M
Hot Swapping the Switch Module
Any of the HP ProCurve Switch Modules can be “hot swapped”, that is installed
or replaced while the switch is powered on. The procedures differ slightly,
though, between adding a new module to the empty slot or replacing the
module with the same type, and exchanging the module with a different type.
C a u t i o n
The
gigabit transceivers
that provide the ports for the Gigabit Stacking
Module for the Switch 2424M are NOT hot swappable. The transceivers must
be installed, removed, or replaced when the module is not receiving power
from the switch, either by installing the transceivers before installing the
module, removing the module from the switch before installing or removing
the transceivers, or powering off the switch before installing or removing the
transceivers. Please see the installation guide that came with your Gigabit
Stacking Module or Gigabit Transceivers for more information.
Adding or Replacing the Module
If a module has to be replaced with one of the same type, or you are expanding
the switch capability by adding a module for the first time, the replaced or
new module is immediately operational; there is no interruption to the switch
operation.
Changing the Module Type
If you exchange the module with one of a different type, for example a
100Base-FX module is installed in place of a 10/100Base-T module that was in
the slot, the switch must be rebooted after the new module is installed so the
switch processor can properly initialize and configure the new module type.
You can reboot the switch by any of these methods:
■
select the Reset or Reboot option from the console, web browser inter-
face, or HP TopTools for Hubs & Switches
■
press the Reset button on the switch
■
unplug and plug in the power cord (power cycle)
Until the switch is rebooted, the new module will not operate, the Module
Status LED will continue to blink, and all the LEDs on the module will stay on
continuously.
c2.fm Page 20 Tuesday, January 12, 1999 1:26 PM
Содержание ProCurve 1600M
Страница 2: ......
Страница 3: ...HP ProCurve Switch 1600M and 2424M Installation Guide ...
Страница 8: ......
Страница 18: ......
Страница 40: ...c2 fm Page 22 Tuesday January 12 1999 1 26 PM ...
Страница 52: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......