![HP ProCurve 1600M Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_installation-manual_155303022.webp)
2-4
Installing the Switch 1600M and 2424M
Installation Procedures
In
stalling the Swit
c
h
1600M
a
nd 2424M
1. Prepare the Installation Site
■
Cabling Infrastructure
- Ensure that the cabling infrastructure meets
the necessary network specifications. See the following table for cable
types and lengths, and see appendix B, “Cables and Connectors” for more
information:
Table 2-1.
Summary of Cable Types to Use with the Switch
Port Type
Cable Type
Length Limits
10/100Base-TX
• 10 Mbps operation:
Category 3, 4, or 5, 100-ohm unshielded
twisted-pair (UTP)
• 100 Mbps operation:
Category 5, 100-ohm UTP or shielded
twisted-pair (STP) cable.
100 meters
Note:
Since the 10Base-T operation is through
10/100Base-TX ports, if you ever want to upgrade
the ports to 100Base-T, it would be best to cable
the ports initially with category 5 cable.
For connecting these ports to end nodes or other
MDI ports, use “straight-through” cable; for
connecting to MDI-X ports on hubs or other
switches, use “crossover” cable.
10Base-FL
(on the 10FL
Module)
62.5/125
µ
m or 50/125
µ
m core/cladding
diameter, graded-index, multimode fiber-
optic cables that are fitted with ST
connectors
1 kilometer
100Base-FX
(on the 100FX
Module)
62.5/125
µ
m or 50/125
µ
m core/cladding
diameter, graded-index, multimode fiber-
optic cables that are fitted with SC
connectors
• 412 meters for half-duplex connections
• 2 kilometers for full-duplex connections
Gigabit-SX
(on the Gigabit-SX
Module and the
Gigabit Stacking
Module with SX
transceivers)
62.5/125
µ
m or 50/125
µ
m core/cladding
diameter, graded-index, multimode fiber-
optic cables that are fitted with SC
connectors
• 62.5
µ
m cable:
– 160 MHz*km = 220 meters
– 200 MHz*km = 275 meters
• 50
µ
m cable:
– 400 MHz*km = 500 meters
– 500 MHz*km = 550 meters
Gigabit-LX
(on the Gigabit-LX
Module and the
Gigabit Stacking
Module with LX
transceivers)
single-mode cables fitted with SC
connectors
62.5/125
µ
m or 50/125
µ
m core/cladding
diameter, graded-index, multimode fiber-
optic cables may also be used, but a mode
conditioning patch cord may be needed —
see the
Installation Guide that came with
the module for more information
• single-mode cable - 5 kilometers
• multimode cable - 550 meters
c2.fm Page 4 Tuesday, January 12, 1999 1:26 PM
Содержание ProCurve 1600M
Страница 2: ......
Страница 3: ...HP ProCurve Switch 1600M and 2424M Installation Guide ...
Страница 8: ......
Страница 18: ......
Страница 40: ...c2 fm Page 22 Tuesday January 12 1999 1 26 PM ...
Страница 52: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......