The designated host should begin receiving SNMP traps. If the host is not receiving traps, restart
the HP P6000 Command View service.
Applying a customized host notification list
To apply a customized host notification list to HP P6000 Command View:
1.
From the Initialized Storage System Properties window, click
System options
.
The System Options window opens.
2.
Select
Configure SNMP/event log notification
.
3.
Select
Configure SNMP host notification list
.
4.
Under Replace the host notification list, click
Browse
.
5.
Locate and select the host notification list you created.
6.
On the Configure Host Notification window, click
Send list file
.
7.
Click
OK
.
The hosts in the notification list should begin receiving SNMP traps. If the hosts are not receiving
traps, restart the HP P6000 Command View service in the management server's Services applet.
For array-based management configurations, restart HP P6000 Command View in the Server
Options menu.
Filtering events by severity
The severity levels are:
•
0—Normal (informational only)
•
1—Undetermined (more information is needed to determine severity)
•
2—Warning (not failed but attention is recommended or required)
•
3—Critical (failure or failure is imminent)
To select a severity level:
1.
From the Initialized Storage System Properties window, click
System options
.
The System Options window opens.
2.
Select
Configure SNMP/event log notification
.
3.
Select
Configure events for SNMP host notification
.
4.
Under Configure events individually, select one or more of the following options:
•
All events
•
Critical events
•
Warning events
•
Normal events
5.
Click
Configure
.
6.
Select one of the following options:
•
Default
•
Notify all
•
None
7.
When you finish configuring event notification, click
OK
.
The System Options window opens. You will now receive only events of the severity you
selected.
Configuring event notification
55