HP OfficeConnect 1850 24G 2XGT Скачать руководство пользователя страница 8

SFP/SFP+ installation notes

NOTE:

To ensure proper operation of your switch, use only the genuine HPE Aruba SFP/SFP+

transceivers supported by your switch. When selecting a fiber SFP device, make sure it can
function at a temperature that is not less than the recommended maximum operational temperature
of the product. Use only approved Laser Class 1 SFP transceivers.

Use only genuine HPE Aruba SFP/SFP+ transceivers

Non-HPE Aruba SFP/SFP+ transceivers are not supported. Use of genuine .HPE Aruba products
ensures that your network maintains optimal performance and reliability. Should you require
additional transceivers, please contact an HPE Aruba sales representative or an authorized
reseller. For transceiver support information, see the QuickSpec for your switch model, or the
following two support matrixes in the Hewlett Packard Enterprise Information Library at

www.hpe.com/networking/ResourceCenter

:

HPE Net working Legacy ProCurve Product Family Mini-GBIC and SFP Support Matrix

HPE Networking Legacy ProCurve Product Family 10–GBE Transceiver Support Matrix

Hot Swapping SFP/SFP+ transceivers

Supported SFP/SFP+ transceivers that you can install in your HPE switch can be “hot swapped”
– removed and installed while the switch is receiving power. However, you should disconnect
the network cables from the SFP/SFP+ transceivers before hot-swapping them.

When you replace an SFP/SFP+ transceiver with another of a different type, the switch may
retain selected port-specific configuration settings that were configured for the replaced unit. Be
sure to validate or reconfigure port settings as required.

SFP/SFP+ connections to devices with fixed speed/duplex configurations

When connecting a device to your switch port that contains an SFP/SFP+ transceiver, the speed
and duplex settings of the switch port and the connected device must match. Otherwise, you
may not get a link. For some older network devices, including some older Hewlett Packard
Enterprise devices, the default speed/duplex settings may be predefined (for example, to 1000
Mbps/Full Duplex), or otherwise set differently from the default configuration of your switch port.
Because of these default speed/duplex considerations, you should make sure that devices
connected to your SFP/SFP+ ports are properly configured.

At a minimum, make sure the

configurations match.

SFP/SFP+ Transceiver regulatory compliance

Use SFP+ transceivers that meet the following regulatory requirements:

Class 1

EN60825-1:2007 2nd Edition or later, European standard

FCC 21 CFR Chapter 1, Subchapter J in accordance with FDA and CDRH requirements

Application of CE Mark in accordance with 2014/30/EU EMC Directive and the 2014/35/EU
Low Voltage Directives

UL and/or CSA registered component for North America

47 CFR Part 15, Class A when installed into Hewlett-Packard Enterprise Products

Switch operating system software

For the latest software version supported by your switch, visit

http://www.hpe.com/networking/

support

.

8

HPE OfficeConnect 1850 Switch Series Quick Setup Guide and Safety/Regulatory Information

Содержание OfficeConnect 1850 24G 2XGT

Страница 1: ...50 switches HPE OfficeConnect 1850 6XGT 2XGT SFP Switch JL169A nl HPE OfficeConnect 1850 24G 2XGT Switch JL170A nl HPE OfficeConnect 1850 48G 4XGT Switch JL171A nl HPE OfficeConnect 1850 24G 2XGT PoE 185W Switch JL172A nl HPE OfficeConnect 1850 48G 4XGT PoE 370W Switch JL173A 5200 0093 Part Number 5200 0093 Published May 2016 Edition 1 6HPQSGEN 01G Printed in China ...

Страница 2: ...cense from Hewlett Packard Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Ente...

Страница 3: ...ly grounded then use the power cord supplied with the switch to connect to the AC power source If your installation requires a different power cord than the one supplied with the switch and or power supply be sure the cord is adequately sized for the switch s current requirements In addition be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power...

Страница 4: ... at the back of the switch and then into an electrical outlet 4 Mount the switch Unplug the AC power from the switch before mounting it Rack mounting Use a 1 Phillips cross head screwdriver to attach the accessory kit brackets to the switch using the eight 8 mm M4 screws Then use four 12 24 screws to secure the brackets to the rack 24 port and 48 port switches NOTE The HPE OfficeConnect 24 port an...

Страница 5: ... mark the position for the mounting screws The hole to hole distance is 3 54 inch 90mm Use a 1 Phillips cross head screwdriver and two of the included 20 mm M4 tap screws Set the screw heads approximately 2mm away from the mounting surface to allow the switch to slide onto the screws Wall anchors are included in the accessory kit for use with plastered brick or concrete walls For under table mount...

Страница 6: ...w it to communicate with the switch through your PC s Web browser Switch factory default settings Factory Default Setting Parameter blank Password DHCP Defaults to 192 168 1 1 if a DHCP address cannot be obtained IP address 255 255 255 0 Subnet mask not set Default gateway Modify the switch s IP configuration to operate in your network See Example Initial Switch Configuration page 7 7 Connect the ...

Страница 7: ...fault IP address http 192 168 1 1 to access the switch s Web interface 3 Click Log on to log on to the switch The default username is admin There is no default password 4 Click Network Setup Get Connected and configure IP network settings on the switch for operation on your network IMPORTANT When the switch starts it attempts to obtain an IP address from a DHCP server If the DHCP server is unreach...

Страница 8: ... type the switch may retain selected port specific configuration settings that were configured for the replaced unit Be sure to validate or reconfigure port settings as required SFP SFP connections to devices with fixed speed duplex configurations When connecting a device to your switch port that contains an SFP SFP transceiver the speed and duplex settings of the switch port and the connected dev...

Страница 9: ...121 0737 South Africa 8121 1071 Brazil 8121 0738 Switzerland 8121 0735 Chile 8121 0964 Taiwan 8121 0943 China 8121 0734 Thailand 8121 0731 Continental Europe South Korea 8121 0739 United Kingdom Hong Kong nl 8121 0733 Denmark Singapore Malaysia 8121 1141 United States Canada Mexico 8121 0564 India HPE 1850 48G 4XGT PoE 370W Switch JL173A 8121 1478 Israel 8121 1481 Argentina 8121 1482 Japan 8121 14...

Страница 10: ...Switch JL170A 0 4 A 200 240 V 50 60 Hz 1 0 A nl 100 127 V nl HPE 1850 48G Switch JL171A 0 6 A 200 240 V AC power frequency range PoE available power Maximum AC Current Rated AC voltage Electrical PoE 50 60 Hz 185 W 2 5 A nl 100 127 V nl HPE 1850 24G PoE 185W Switch JL172A 1 3 A 200 240 V 50 60 Hz 370 W 5 0 A 100 127 V nl HPE 1850 48G PoE 370W Switch JL173A nl 2 4 A 200 240 V 1850 8XG 1850 24G 1 4 ...

Страница 11: ... Sound Power LwA 4 5 Bel HPE OfficeConnect 1850 6XGT 2XGT SFP Switch JL169A Sound Pressure LpAm Bystander 37 9 dB Sound Power LwA 3 6 Bel HPE OfficeConnect 1850 24G 2XGT Switch JL170A Sound Pressure LpAm Bystander 30 5 dB Sound Power LwA 3 4 Bel HPE OfficeConnect 1850 48G 4XGT Switch JL171A Sound Pressure LpAm Bystander 30 5 dB Sound Power LwA 4 4 Bel HPE OfficeConnect 1850 24G 2XGT PoE 185W Switc...

Страница 12: ...is equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ...

Страница 13: ...eds To help us improve the documentation send any errors suggestions or comments to Documentation Feedback docsfeedback hpe com When submitting your feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices pag...