![HP NonStop SQL/MX Скачать руководство пользователя страница 622](http://html.mh-extra.com/html/hp/nonstop-sql-mx/nonstop-sql-mx_messages-manual_165150622.webp)
Versioning and Distribution Messages (25000
through 25399)
HP NonStop SQL/MX Messages Manual — 640324-001
19- 8
version2
is the compiler version of the compiler that executes the DDL or utility
operation.
Cause. The affected DDL or utility operation references a database object in a
schema with a schema version that is higher than the compiler version of the compiler
that executes the operation. This can happen if one of these is true:
•
A downrev compiler is explicitly being used to execute the operation.
•
The operation references an object in a remote uprev schema.
Effect. The request fails.
Recovery. Depending on the actual cause:
•
Do not explicitly use a downrev compiler to execute the operation.
•
Execute the operation from a node where the schema is defined.
SQL 25206
where,
node
is the name of the node with an incompatible version system schema.
version1
is the system schema version of
node
.
version2
is the compiler version of the compiler that compiles the query or executes
the DDL or utility operation.
Cause. The affected query compilation, DDL, or utility operation need to access
system schema tables with a system schema version that is incompatible with the
version of the compiler that compiles the query and executes the operation. This can
happen if:
•
The local system schema version is later than the MXV of a node that is involved in
the affected query. Compilation of such a query requires a downrev compiler.
•
The local system schema version is higher than the schema version of a schema
that is involved in a DDL or Utility operation. Execution of such an operation
requires a downrev compiler.
•
There is a need to access the system schema on a remote uprev node, and the
system schema version of that system schema is later than the current compiler
version.
Effect. The request fails.
Recovery. Downgrade the system schema on the affected node to a version that is
compatible with the required compiler version.
25206 The system schema on node
node
has system schema
version
version1
; this is incompatible with the version of
the compiler. The compiler version is
version2
.
Содержание NonStop SQL/MX
Страница 4: ......
Страница 8: ...Contents HP NonStop SQL MX Messages Manual 640324 001 iv ...
Страница 26: ...General Messages 0 through 999 HP NonStop SQL MX Messages Manual 640324 001 2 2 ...
Страница 130: ...SQL MX MXCMP Messages 2000 through 2999 HP NonStop SQL MX Messages Manual 640324 001 4 34 ...
Страница 186: ...Parser and Compilation Messages 3000 through 3999 HP NonStop SQL MX Messages Manual 640324 001 5 56 ...
Страница 242: ...Normalizer Messages 5000 through 5999 HP NonStop SQL MX Messages Manual 640324 001 7 2 ...
Страница 246: ...Optimizer Messages 6000 through 6999 HP NonStop SQL MX Messages Manual 640324 001 8 4 ...
Страница 248: ...Generator Messages 7000 through 7999 HP NonStop SQL MX Messages Manual 640324 001 9 2 ...
Страница 360: ...Trigger UDR Server and Language Manager Messages 11000 through 11399 HP NonStop SQL MX Messages Manual 640324 001 13 30 ...
Страница 472: ...Messages Generated by the Message System 16000 through 16999 HP NonStop SQL MX Messages Manual 640324 001 16 2 ...
Страница 614: ...Utility Messages 20000 through 23099 HP NonStop SQL MX Messages Manual 640324 001 18 138 ...
Страница 738: ...SQLSTATE Values Returned by NonStop SQL MX HP NonStop SQL MX Messages Manual 640324 001 21 86 SQLSTATE Values ...
Страница 752: ...Non SQLCODE Error Messages HP NonStop SQL MX Messages Manual 640324 001 A 14 MXGNAMES Utility ...