Table 9-2
Power-on diagnostic test
Test
Description
Boot Block Checksum
Tests boot block code for proper checksum value
DRAM
Simple write/read pattern test of the first 640k of memory
Serial Port
Tests the serial port using simple port verification test to determine if ports are present
Timer
Tests timer interrupt by using polling method
RTC CMOS battery
Tests integrity of RTC CMOS battery
NAND flash device
Tests for proper NAND flash device ID present
Interpreting POST diagnostic front panel LEDs and audible codes
This section covers the front panel LED codes as well as the audible codes that may occur before or during
POST that do not necessarily have an error code or text message associated with them.
WARNING!
When the computer is plugged into an AC power source, voltage is always applied to the system
board. To reduce the risk of personal injury from electrical shock and/or hot surfaces, be sure to disconnect
the power cord from the wall outlet and allow the internal system components to cool before touching.
NOTE:
Recommended actions in the following table are listed in the order in which they should be
performed.
Not all diagnostic lights and audible codes are available on all models.
Table 9-3
Diagnostic front panel LEDs and audible codes
Activity
Beeps
Possible Cause
Recommended Action
White Power LED On.
None
Computer on.
None
White Power LED flashes every
two seconds.
None
Computer in Suspend to
RAM mode (some models
only) or normal Suspend
mode.
No action required. Press any key or move the mouse
to wake the computer.
Red Power LED flashes two
times, once every second,
followed by a two second pause.
Beeps stop after fifth iteration
but LEDs continue until problem
is solved.
2
Processor thermal
protection activated:
A fan may be blocked or not
turning.
OR
The heat sink/fan assembly
is not properly attached to
the processor.
OR
The unit has vents blocked
or is in a location where the
ambient temperature is too
high.
1.
Ensure that the computer air vents are not
blocked and the processor cooling fan is
plugged in and running, if equipped.
2.
Contact an authorized reseller or service
provider.
Red Power LED flashes four
times, once every second,
followed by a two second pause.
4
Power failure (power supply
is overloaded).
OR
1.
Check if a device is causing the problem by
removing ALL attached devices. Power on the
system. If the system enters the POST, then
Interpreting POST diagnostic front panel LEDs and audible codes
75