McDATA® 4Gb SAN Switch for HP p-Class BladeSystem installation guide
19
2
Planning
Consider the following when planning a fabric:
•
•
•
•
•
•
•
Devices
When planning a fabric, consider the number of public devices and the anticipated demand. This will
determine the number of ports that are needed and in turn the number of switches. See the
HP
StorageWorks SAN Design
Guide for more information.
For the two external FC ports, the switch uses SFP optical transceivers, but the device you are connecting to
these ports may not. Consider whether the FC ports on the device use SFP or Gigabit Interface Converters
(GBIC) transceivers, and choose fiber optic cables accordingly. Use LC-type cable connectors for SFP
transceivers and SC-type cable connectors for GBIC transceivers. Also consider the transmission speed
compatibility of your devices, HBAs, switches, and SFPs.
Consider the distribution of targets and initiators. An F_Port supports a single public device. An FL_Port can
support up to 32 public devices in an arbitrated loop.
Device access
Consider device access needs within the fabric. Access is controlled by the use of zones and zone sets.
Some zoning strategies include the following:
•
Group devices by operating system.
•
Separate devices that have no need to communicate with other devices in the fabric or have classified
data.
•
Separate devices into department, administrative, or other functional group.
A zone is a named group of devices that can communicate with each other. Membership in a zone can be
defined by switch domain ID and port number, or by device worldwide name (WWN). Devices can
communicate only with devices within the same zone. The switch supports one zone set; that is, the active
zone set. The active zone set contains the zones that determine the current fabric zoning.
Zoning divides the fabric for purposes of controlling device discovery. Devices in the same zone
automatically discover and communicate freely with all other members of the same zone. The following
rules apply to zones:
•
Zones that include members from multiple switches need not include the ports of the inter-switch links.
•
Zones can overlap; that is, a port can be a member of more than one zone.
•
Membership can be defined by domain ID and port number, or port worldwide name.
•
Zoning supports FL_Ports and F_Ports.