Appendix A The Error Codes
1000h – 100Dh:
Multiple Processor Error Codes
76
English
1000h – 100Dh:
Multiple Processor Error Codes
0F04h
Seek operation failed.
If the seek function is supported by the device
controller, replace the controller.
0F05h
Eject fails on drive x.
The eject feature is not supported or does not work.
Re-run the diagnostics test.
Code
Explanation
Details/Parts to Check
1000h
Processors don't have unique IDs.
Processor ID error.
Check that the processor is correctly configured.
1001h
Processor X failed to interrupt processor
Y.
Processor error.
Install a new processor.
1002h
IPI physical mode test failed on processor
X.
Processor error.
Install a new processor.
1008h
MPI arbitration test failed.
Processor error.
Check that the processor is correctly configured.
If the error persists, install new processor.
1009h
Cache coherency test failed.
Processor error.
Check that the processor is correctly configured.
If the error persists, install new processor.
100Ah
Memory consistency test failed.
Processor error.
Check that processor is
Install a new processor.
100Bh
I/O access test failed on processor X at
port XXXXh.
Processor error.
Install a new processor.
Code
Explanation
Details/Parts to Check
guard.bk : g-e-ref1.fb4 Page 76 Wednesday, June 30, 1999 3:06 PM
Содержание Kayak XU04
Страница 3: ...User s Guide guard bk title fb4 Page iii Wednesday June 30 1999 3 06 PM ...
Страница 12: ...xii English guard bk guard toc Page xii Wednesday June 30 1999 3 06 PM ...
Страница 36: ...3 Basic System Test What is Tested 24 English guard bk guard3 fb4 Page 24 Wednesday June 30 1999 3 06 PM ...
Страница 49: ...6 HP Customer Care Service and Support guard bk guard6 fb4 Page 37 Wednesday June 30 1999 3 06 PM ...
Страница 95: ...guard bk guard bc fb4 Page 83 Wednesday June 30 1999 3 06 PM ...
Страница 96: ...Part Number TBD DiagTools User s Guide guard bk guard bc fb4 Page 84 Wednesday June 30 1999 3 06 PM ...