Troubleshooting
The front of the RPS provides a quick reference troubleshooting guide. For
more details use the following table to diagnose your RPS.
LED
State
Meaning of LED
AC Power
(green)
On
Off
Flash
The RPS is receiving power.
The RPS is not receiving power on both AC inputs.
The RPS is not receiving power from one of the AC inputs. Verify that both of the AC
power cords are plugged into an operating AC power source.
DC Power Out
(green)
On
Off
Flash
A device is connected to the DC Power Out connector and is receiving redundant power.
A device is not connected to one of the DC Output connectors. Verify the device is
connected properly. If the connector appears snug on both ends, try using a different DC
power cord.
A device is connected to the RPS but one of the DC to DC converters has failed. The
other DC to DC is still providing power. Call your HP Authorized Dealer or the nearest
HP Sales and Support office.
Overtemp
(orange
)
Off
Flash
The RPS is running at a normal temperature.
The RPS has reached 70°C or higher, and needs more adequate ventilation.
Fan
(green)
On
Flash
The fans are on and operating normally.
One or both of the fans has malfunctioned.
Fault
(orange)
Off
Flash
No faults have been detected on the RPS.
A failure has been detected. The corresponding LED will also flash.
Troubleshooting